Denon AVR 2808CI Owners Manual - English - Page 33

Zone Setup - who can fix a

Page 33 highlights

Getting Started Connections Setup Playback Remote Control Multi-Zone Information Troubleshooting Zone Setup Make settings for audio playback in a multi-zone system. F Menu screen F 2.Manual Setup 1.Speaker Setup 2.HDMI Setup 3.Audio Setup 4.Zone Setup 5.Option Setup 2-4.Zone Setup 1.ZONE2 Setup 2.ZONE3 Setup Lch Level Adjust the left channel output level. [Variable range] -12dB ~ 0dB ~ +12dB Rch Level Adjust the right channel output level. [Variable range] -12dB ~ 0dB ~ +12dB Volume Limit Make a setting for maximum volume. [Selectable items] OFF : Do not set a maximum volume. -20dB : Set the maximum volume to -20 dB. -10dB : Set the maximum volume to -10 dB. 0dB : Set the maximum volume to 0 dB. a ZONE2 Setup Make settings for audio playback in a ZONE2 system. s ZONE3 Setup Make settings for audio playback in a ZONE3 system. Bass Adjust low frequency range (bass). [Variable range] -10dB ~ 0dB ~ +10dB Treble Adjust high frequency range (treble). [Variable range] -10dB ~ 0dB ~ +10dB HPF Channel Switch between stereo and mono output. [Selectable items] Stereo : Select stereo output. Mono : Select monaural output. When menu "Manual Setup" - "Option Setup" - "Amp Assign" (vpage 31) is set to ZONE2/3-MONO", the "Channel" setting is automatically set to "Mono". Volume Level Adjust the main volume level. [Selectable items] VAR : Allow volume adjustment by remote control. -40dB : Fix the volume to -40 dB. 0dB : Fix the volume to 0 dB. Power On Level Define the volume setting that is active when the power is turned on. [Selectable items] Last : Use the memorized setting from the last session. - - - : Always use the muting on condition when power is turned on. -70dB ~ +18dB : Set the volume level when the power is turned on in units of 1 dB. Mute Level Set the amount of attenuation when muting is on. [Selectable items] Full : The sound is cut off entirely. -40dB : The sound is attenuated by 40 dB. -20dB : The sound is attenuated by 20 dB. When using speakers that cannot satisfactorily play low frequencies, distortion of the bass sound can be reduced by setting "HPF" to "ON". [Selectable items] "VAR" is displayed when a power amplifier is assigned to the ZONE2 output channel at menu "Manual Setup" - "Option Setup" - "Amp Assign" (vpage 31). OFF : The low range is not attenuated. ON : The low range is attenuated. 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93

Zone Setup
Make settings for audio playback in a multi-zone system.
F
Menu screen
F
2.Manual Setup
2.HDMI Setup
1.Speaker Setup
4.Zone Setup
5.Option Setup
3.Audio Setup
a
ZONE2 Setup
Make settings for audio playback in a ZONE2 system.
s
ZONE3 Setup
Make settings for audio playback in a ZONE3 system.
Bass
Adjust low frequency range (bass).
[Variable range]
–10dB
~
0dB
~
+10dB
Treble
Adjust high frequency range (treble).
[Variable range]
–10dB
~
0dB
~
+10dB
HPF
When using speakers that cannot satisfactorily play low frequencies,
distortion of the bass sound can be reduced by setting “HPF” to
“ON”
.
[Selectable items]
OFF
:
The low range is not attenuated.
ON
:
The low range is attenuated.
Lch Level
Adjust the left channel output level.
[Variable range]
–12dB
~
0dB
~
+12dB
Rch Level
Adjust the right channel output level.
[Variable range]
–12dB
~
0dB
~
+12dB
Channel
Switch between stereo and mono output.
[Selectable items]
Stereo
:
Select stereo output.
Mono
:
Select monaural output.
When menu “Manual Setup” – “Option Setup” – “Amp Assign”
(
v
page 31) is set to ZONE2/3-MONO”
, the “Channel” setting is
automatically set to “Mono”
.
2.ZONE3 Setup
1.ZONE2 Setup
2-4.Zone Setup
Volume Limit
Make a setting for maximum volume.
[Selectable items]
OFF
:
Do not set a maximum volume.
–20dB
:
Set the maximum volume to –20 dB.
–10dB
:
Set the maximum volume to –10 dB.
0dB
:
Set the maximum volume to 0 dB.
Power On Level
Define the volume setting that is active when the power is turned on.
[Selectable items]
Last
:
Use the memorized setting from the last session.
– – –
:
Always use the muting on condition when power
is turned on.
–70dB ~ +18dB
:
Set the volume level when the power is turned on
in units of 1 dB.
Mute Level
Set the amount of attenuation when muting is on.
[Selectable items]
Full
:
The sound is cut off entirely.
–40dB
:
The sound is attenuated by 40 dB.
–20dB
:
The sound is attenuated by 20 dB.
Volume Level
Adjust the main volume level.
[Selectable items]
VAR
:
Allow volume adjustment by remote control.
–40dB
:
Fix the volume to –40 dB.
0dB
:
Fix the volume to 0 dB.
“VAR” is displayed when a power amplifier is assigned to the ZONE2
output channel at menu “Manual Setup” – “Option Setup” – “Amp
Assign” (
v
page 31).
³0
Getting Started
Connections
Setup
Playback
Remote Control
Multi-Zone
Information
Troubleshooting