V.5.6.0 Protocol specification The following three data forms are defined. COMMAND : The message sent to a system(DVP-602CI) from a controller(Touch Panel etc.) A command to a system is given from a controller. EVENT : The message sent to a controller(Touch Panel etc.) from a system(DVP-602CI) The result is sent, when a system is operated directly and a state changes. *The form of EVENT presupposes that it is the same as that of COMMAND. **Refer to the following table for the contents of COMMAND and EVENT. RESPONSE : The message sent to a controller(Touch Panel etc.) from a system(DVP-602CI) if the 'request command' (COMMAND+?+CR(0x0D)) has came from a controller. The RESPONSE should be sent within 200ms of receiving the COMMAND. *The form of RESPONSE presupposes that it is the same as that of EVENT. Basic specification : The command by ASCII CODE, parameter expression *ASCII CODE which can be used is from 0x20 to 0x7F : the alphabet and the number of 0-9 , and space (0x20) , Some signs , AND carriage return(0x0D)--- It is used only as a pause sign. Command structure : COMMAND + PARAMETER + CR(0x0D) COMMAND : ASCII CODE of 2 characters ex. SI : Select Input source PW : system PoWer setting PARAMETER : ASCII CODE ( up to 25 characters) ex. HDMI1 : function name COM1 : function name *Special Parameter--- ? : for request command - 4 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

V.5.6.0
- 4 -
Protocol specification
The following three data forms are defined.
COMMAND
:
The message sent to a system(DVP-602CI) from a controller(Touch Panel etc.)
A command to a system is given from a controller.
EVENT
:
The message sent to a controller(Touch Panel etc.) from a system(DVP-602CI)
The result is sent, when a system is operated directly and a state changes.
*The form of
EVENT
presupposes that it is the same as that of
COMMAND
.
**Refer to the following table for the contents of
COMMAND
and
EVENT
.
RESPONSE
:
The message sent to a controller(Touch Panel etc.) from a system(DVP-602CI)
if the ‘request command’ (
COMMAND
+
?
+CR(0x0D)) has came from a controller.
The
RESPONSE
should be sent within 200ms
of receiving the
COMMAND
.
*The form of
RESPONSE
presupposes that it is the same as that of
EVENT
.
Basic specification
: The command by ASCII CODE, parameter expression
*ASCII CODE which can be used is from 0x20 to 0x7F : the alphabet and the number of 0-9 , and space (0x20) , Some signs ,
AND carriage return(0x0D)--- It is used only as a pause sign.
Command structure
: COMMAND + PARAMETER + CR(0x0D)
COMMAND : ASCII CODE of 2 characters
ex.
SI
:
Select Input source
PW
:
system PoWer setting
PARAMETER : ASCII CODE ( up to 25 characters)
ex.
HDMI1 : function name
COM1 : function name
*Special Parameter--- ? : for request command