Dewalt DCD792B Instruction Manual - Page 13

OPERATION, Installing and Removing the Battery Pack, Fig. K, Proper Hand Position Fig. L,

Page 13 highlights

swallowed, it can cause severe internal burns in just 2 hours and can lead to death. • Keep new and used batteries away from children. If the battery compartment does not close securely, stop using the product and keep it away from children. • If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention. • If the coin cell battery contents come into contact with the skin, immediately wash area with mild soap and water. If coin cell battery liquid gets into the eye, rinse water over the open eye for 15 minutes or until irritation ceases. If medical attention is needed, the battery electrolyte is composed of an organic solvent and lithium salts. • Do not incinerate or dispose of tool together with household waste material! Tool that has reached the end of its life must be collected separately and returned to an environmentally compatible recycling facility. OPERATION WARNING: To reduce the risk of serious personal injury, turn unit off and remove the battery pack before making any adjustments or removing/ installing attachments or accessories. An accidental start-up can cause injury. Exception-Tool Connect™ functions and mode adjustments require battery to be installed. NOTICE: Always check the tool configuration prior to use. If you are unsure of the current configuration, press the mode selector button 12 (Fig. J) to set the tool to the Home setting as described on the label and this manual. Installing and Removing the Battery Pack (Fig. K) NOTE: For best results, make sure your battery pack is fully charged. To install the battery pack 11 into the tool handle, align the battery pack with the rails inside the tool's handle and slide it into the handle until the battery pack is firmly seated in the tool and ensure that it does not disengage. To remove the battery pack from the tool, press the release button 10 and firmly pull the battery pack out of the tool handle. Insert it into the charger as described in the charger section of this manual. Fig. K 11 10 English Proper Hand Position (Fig. L) WARNING: To reduce the risk of serious personal injury, ALWAYS use proper hand position as shown. WARNING: To reduce the risk of serious personal injury, ALWAYS hold securely in anticipation of a sudden reaction. Proper hand position requires one hand on the main handle and one hand on the battery pack. Fig. L Screwdriving (Fig. D) 1. Select the desired speed/torque range using the gear shifter to match the speed and torque to the planned operation. 2. Turn the torque adjustment collar 3 to the desired position. NOTE: Use the lowest torque setting required to seat the fastener at the desired depth. The lower the number, the lower the torque output. 3. Insert the desired fastener accessory into the chuck as you would any drill bit. 4. Make some practice runs in scrap or on unseen areas of the workpiece to determine the proper position of the torque adjustment collar. 5. Always start with lower torque settings, then advance to higher torque settings to avoid damage to the workpiece or fastener. Drilling (Fig. E) NOTICE: If drilling thin material, use a wood "backup" block to prevent damage to the material. 1. Select the desired speed/torque range using the gear shifter to match the speed and torque to the planned operation. Turn the collar 3 to the drill symbol. 2. Use sharp drill bits only. For MASONRY, such as brick, cement, cinder block, etc., use carbide-tipped bits rated for percussion drilling. 3. Always apply pressure in a straight line with the bit. Use enough pressure to keep drill biting, but do not push hard enough to stall the motor or deflect the bit. 4. Hold tool firmly with both hands to control the twisting action of the drill. If model is not equipped with side handle, grip drill with one hand on the handle and one hand on the battery pack. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

ENGLISH
11
swallowed, it can cause severe internal burns in just
2 hours and can lead to death.
Keep new and used batteries away from children.
If the battery compartment does not close
securely, stop using the product and keep it away
from children.
If you think batteries might have been swallowed
or placed inside any part of the body, seek
immediate medical attention.
If the coin cell battery contents come into contact
with the skin, immediately wash area with mild
soap and water. If coin cell battery liquid gets
into the eye, rinse water over the open eye for
15 minutes or until irritation ceases. If medical
attention is needed, the battery electrolyte is
composed of an organic solvent and lithium salts.
Do not incinerate or dispose of tool together with
household waste material! Tool that has reached
the end of its life must be collected separately
and returned to an environmentally compatible
recycling facility.
OPERATION
±
WARNING: To reduce the risk of serious personal
injury, turn unit off and remove the battery pack
before making any adjustments or removing/
installing attachments or accessories.
An
accidental start-up can cause injury. Exception—Tool
Connect™ functions and mode adjustments require
battery to be installed.
NOTICE:
Always check the tool configuration prior
to use. If you are unsure of the current configuration,
press the mode selector button
12
(Fig. J) to set the
tool to the Home setting as described on the label and
this manual.
Installing and Removing the Battery Pack
(Fig. K)
NOTE:
For best results, make sure your battery pack is
fully charged.
To install the battery pack
 11 
into the tool handle, align the
battery pack with the rails inside the tool’s handle and slide
it into the handle until the battery pack is firmly seated in
the tool and ensure that it does not disengage.
To remove the battery pack from the tool, press the release
button
 10 
and firmly pull the battery pack out of the tool
handle. Insert it into the charger as described in the charger
section of this manual.
Fig. K
10
11
Proper Hand Position (Fig. L)
±
WARNING:
To reduce the risk of serious personal injury,
ALWAYS
use proper hand position as shown.
±
WARNING:
To reduce the risk of serious personal
injury,
ALWAYS
hold securely in anticipation of a
sudden reaction.
Proper hand position requires one hand on the main handle
and one hand on the battery pack.
Fig. L
Screwdriving (Fig. D)
1. Select the desired speed/torque range using the
gear shifter to match the speed and torque to the
planned operation.
2. Turn the torque adjustment collar
 3 
to the
desired position.
NOTE:
Use the lowest torque setting required to
seat the fastener at the desired depth. The lower the
number, the lower the torque output.
3. Insert the desired fastener accessory into the chuck as
you would any drill bit.
4. Make some practice runs in scrap or on unseen areas of
the workpiece to determine the proper position of the
torque adjustment collar.
5. Always start with lower torque settings, then advance
to higher torque settings to avoid damage to the
workpiece or fastener.
Drilling (Fig. E)
NOTICE:
If drilling thin material, use a wood “back-
up” block to prevent damage to the material.
1. Select the desired speed/torque range using the gear
shifter to match the speed and torque to the planned
operation. Turn the collar
 3 
to the drill symbol.
2. Use sharp drill bits only. For MASONRY, such as brick,
cement, cinder block, etc., use carbide-tipped bits rated
for percussion drilling.
3. Always apply pressure in a straight line with the bit. Use
enough pressure to keep drill biting, but do not push
hard enough to stall the motor or deflect the bit.
4. Hold tool firmly with both hands to control the twisting
action of the drill. If model is not equipped with side
handle, grip drill with one hand on the handle and one
hand on the battery pack.