English reaches cut-out pressure, the check valve closes, allowing air pressure to remain inside the air tank. AIR INTAKE FILTER The filter (A) is designed to clean air entering the A pump. To ensure the pump continually receives a clean, cool, and dry air supply the filter must always be clean and the filter intake must be free from obstructions. AIR TANK DRAIN VALVE The drain valve (H) is located at the base of the air tank and is used to drain condensation at the end of each use. See Draining Air Tank under Maintenance. H REGULATED PRESSURE GAUGE The regulated pressure gauge (D) indicates the air pressure available at the outlet side of the regulator. This D C pressure is controlled by the regulator and is always less or equal to the air tank pressure. TANK PRESSURE GAUGE The tank pressure gauge (C) indicates the reserve air pressure in the tank. UNIVERSAL QUICK CONNECT BODY L The universal quick connect body (L) E accepts the three most popular styles of quick connect plugs: Industrial, automotive, and ARO. One hand push-to-connect operation makes connections simple and easy. REGULATOR The regulator knob (E) controls the air pressure coming from the air tank. To Adjust Regulator: 1. Pull regulator knob (E) out. 2. Turn knob clockwise to increase regulated pressure and counter-clockwise to decrease regulated pressure. 3. When desired pressure is shown on the regulated pressure gauge push knob in to lock. WARNING: Risk of Bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer's maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating. AIR COMPRESSOR PUMP The pump compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet. MOTOR OVERLOAD PROTECTOR The motor has a thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The M motor must be allowed to cool down before restarting. To restart: 1. Set the Auto/Off switch to OFF (O) and unplug unit. 2. Allow the motor to cool. 3. Depress the red reset button (M) on the motor. 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

10
English
reaches cut-out pressure, the check valve closes, allowing air
pressure to remain inside the air tank.
AIR INTAKE FILTER
The filter (A) is designed to clean air entering the
A
pump. To ensure the pump continually receives a
clean, cool, and dry air supply the filter must always
be clean and the filter intake must be free from
obstructions.
AIR TANK DRAIN VALVE
The drain valve (H) is located at the base
H
of the air tank and is used to drain
condensation at the end of each use.
See Draining Air Tank under
Maintenance
.
REGULATED PRESSURE GAUGE
The regulated pressure gauge (D)
indicates the air pressure available at
the outlet side of the regulator. This
pressure is controlled by the regulator
and is always less or equal to the air
tank pressure.
TANK PRESSURE GAUGE
The tank pressure gauge (C) indicates
the reserve air pressure in the tank.
UNIVERSAL QUICK CONNECT
BODY
The universal quick connect body (L)
accepts the three most popular styles
of quick connect plugs: Industrial,
automotive, and ARO. One hand push-to-connect operation makes
connections simple and easy.
REGULATOR
The regulator knob (E) controls the air pressure coming from the air
tank.
To Adjust Regulator:
1. Pull regulator knob (E) out.
2. Turn knob clockwise to increase regulated pressure and
counter-clockwise to decrease regulated pressure.
3. When desired pressure is shown on the regulated pressure
gauge push knob in to lock.
WARNING:
Risk of Bursting. Too much air pressure causes a
hazardous risk of bursting. Check the manufacturer’s maximum
pressure rating for air tools and accessories. The regulator outlet
pressure must never exceed the maximum pressure rating.
AIR COMPRESSOR PUMP
The pump compresses air into the air tank. Working air is not available
until the compressor has raised the air tank pressure above that
required at the air outlet.
MOTOR OVERLOAD PROTECTOR
The motor has a thermal overload protector.
M
If the motor overheats for any reason, the
overload protector will shut off the motor. The
motor must be allowed to cool down before
restarting. To restart:
1.
Set the Auto/Off switch to OFF (O)
and unplug unit.
2.
Allow the motor to cool.
3.
Depress the red reset button (M) on the motor.
C
D
L
E