Electrolux E15IM60GSS Complete Owner's Guide (English) - Page 5
Installation
View all Electrolux E15IM60GSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Installation 5 Installation Dimensions 14 - 15/16" 24" (37.9) (61) 34 - 1/8" (86.7) FULL RETRACT HEIGHT 5" (12.7) WATER OUTLET WATER DRAIN WATER VALVE 21 - 3/4" (55.2) Installing the Drain CAUTION PLEASE READ all instructions completely before attempting to install or operate the unit. All ice makers require a connection to the water supply and improper hook-up can result in substantial property damage! All water and drain connections MUST BE made by a licensed/qualified plumbing contractor. Failure to follow recommendations and instructions may result in damage and/or harm. • Drain lines must have a 1 inch drop per 48 inches of run (1/4 inch per foot) and must not create traps. • The floor drain must be large enough to accommodate drainage from all drains. • Insulate the bin drain line to prevent condensation. CAUTION Plumbing installation must observe all state and local codes. All water and drain connections MUST BE made by a licensed/ qualified plumbing contractor. Failure to follow recommendations and instructions may result in damage and/or harm. Model EI15IM55GS can be installed using a gravity drain or the Electrolux EIMP60, optional drain pump kit. Follow these guidelines when installing drain lines to prevent water from flowing back into the ice maker storage bin and/or potentially flowing onto the floor causing water damage: Gravity Drain • Drain lines must have a 5/8 inch inside diameter. Figure 1