Electrolux E24WC48EBS Service Manual - Page 13

Problem, Cause, Correction

Page 13 highlights

Problem 7. Excessive frost build-up. Cause 8. Noisy. Cause 9. Fresh food temperature too cold. Cause Cause a. Door gasket not sealing properly. b. Door out of alignment. c. Water soaked cabinet insulation. d. Light stays on when door is closed. a. Copper refrigeration tube touching cabinet. b. Fan blade touching shroud. c. Fan blade obstruction (wiring, foam insulation, packaging material). a. Temperature control set too cold. Correction a. Adjust door hinges or replace door gasket. b. Align fill door hinges. c. Replace foamed cabinet assembly (factoryrepair only). d. Repair light bracket. Remedy a. Carefully adjust tubing. b. Adjust fan mounting or shroud. c. Remove obstruction. Remedy a. Adjust control to warmer setting (counterclockwise). 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

13
Problem
Cause
Correction
7. Excessive frost build-up.
Cause
8. Noisy.
Cause
9. Fresh food temperature too
cold.
Cause
a.
Door gasket not sealing
properly.
b.
Door out of alignment.
c.
Water soaked cabinet
insulation.
d.
Light stays on when door is
closed.
a. Copper refrigeration tube
touching cabinet.
b.
Fan blade touching shroud.
c.
Fan blade obstruction (wiring,
foam insulation, packaging
material).
a.
Temperature control set too
cold.
a. Adjust door hinges or replace
door gasket.
b.
Align fill door hinges.
c. Replace foamed cabinet
assembly (factoryrepair only).
d. Repair light bracket.
Remedy
a. Carefully adjust tubing.
b. Adjust fan mounting or shroud.
c. Remove obstruction.
Remedy
a.
Adjust control to warmer setting
(counterclockwise).