Electrolux E36GC75PSS Installation Instructions (English Español Fran - Page 5
Important, Install Pressure Regulator, Wall Outlet Location, Provide an Adequate Gas Supply, LP/
View all Electrolux E36GC75PSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
GAS COOKTOP INSTALLATION INSTRUCTIONS Wall Outlet Location 4" (10,2 cm) The conversion must be performed by a qualified service technician in accordance with the kit instructions and all local codes and requirements. Failure to follow instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for the conversion. 5" (12,7 cm) Failure to make the appropriate conversion can result in serious personal injury and property damage. Recommended area for 120V grounded outlet on rear wall. NOTE: If an outlet is not available, have one installed by a qualified technician. CENTRE 16" LINE (40,6 cm) OF UNIT Important: Remove all packing material and literature from cooktop before connecting gas and electrical supply to cooktop. Install Pressure Regulator Install the pressure regulator with the arrow on the regulator pointing up toward the unit in a position where you can reach the access cap. Do not make the connection too tight. The regulator is die cast. Overtightening may crack the regulator resulting in a gas leak and possible fire or explosion. Figure 4 CENTRE LINE OF UNIT Provide an Adequate Gas Supply This cooktop is designed to operate on natural gas at 4" (10,2 cm) of manifold pressure only. A pressure regulator is connected in series with the manifold on the cooktop and must remain in series with the supply line. Manual Shutoff Valve Flare Union GAS FLOW Pressure Flare Regulator Union On Nipple Off Flexible Connector Nipple Access Cap All connections must be wrench-tightened Figure 5 For proper operation, the maximum inlet pressure to the regulator must be no more than 14" (35,6 cm) of water column (W.C.) pressure. For checking the regulator, the inlet pressure must be at least 1"(2,5 cm) (or 2,5 kPa) greater than the regulator manifold pressure setting. The regulator is set for 4" (10,2 cm) of manifold pressure, the inlet pressure must be at least 5" (12,7 cm). Assemble the flexible connector from the gas supply pipe to the pressure regulator in the following order: 1. manual shutoff valve 2. 1/2" (1,3 cm) nipple 3. 1/2" (1,3 cm) flare union adapter 4. flexible connector 5. 1/2" (1,3 cm) flare union adapter 6. 1/2" (1,3 cm) nipple 7. pressure regulator The gas supply line to the range should be 1/2" (1,3 cm) or 3/4" (1,9 cm) pipe. LP/Propane Gas Conversion This appliance can be used with Natural gas or LP/ Propane gas. It is shipped from the factory for use with natural gas. Use pipe-joint compound made for use with Natural and LP/Propane gas to seal all gas connections. If flexible connectors are used, be certain connectors are not kinked. A kit for converting to LP gas is supplied with your cooktop. The kit is marked "FOR LP/PROPANE GAS CONVERSION". 5