Electrolux E36GC76GPS Installation Instructions - Page 7
Check Operation - installation
UPC - 057112097985
View all Electrolux E36GC76GPS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
GAS COOKTOP INSTALLATION INSTRUCTIONS Check Operation Refer to the Use and Care Guide packaged with the cooktop for operating instructions and for care and cleaning of your cooktop. Do not touch the burners. They may be hot enough to cause burns. 1. Burner Bases and Burner Caps This range is equipped with sealed burners as shown (Figure 8). All pieces are at their place. Take note where they are. Remove all packaging material located under the Dual Surface burner head. Make sure the burner is properly aligned and leveled. NOTE: There are no burner adjustments necessary on this range. 4. Adjust the "LOW" Setting of Regular Burner (see figure 8) on the Surface Burner Valves (Figure 9): a. Push in and turn control to LITE until burner ignites. b. Quickly turn knob to LOWEST POSITION. c. If burner goes out, reset control to OFF. d. Remove the surface burner control knob and decorative ring. e. Insert a thin-bladed screwdriver into the hollow valve stem and engage the slotted screw inside. Flame size can be increased or decreased by turning the screw. Turn counterclockwise to increase flame size. Turn clockwise to decrease flame size. Adjust flame until you can quickly turn knob from LITE to LOWEST POSITION without extinguishing the flame. Flame should be as small as possible without going out. Note: Air mixture adjustment is not required on surface burners. Figure 8 2. Turn on Electrical Power and Open Main Shutoff Gas Valve 3. Check the Igniters Operation of electric igniters should be checked after range and supply line connectors have been carefully checked for leaks and range has been connected to electric power. To check for proper lighting: a. Push in and turn a surface burner knob to the LITE position. All electronic surface ignitors will spark at the same time. However, only the burner you are turning on will ignite. b.The surface burner should light once the flow of gas reached the surface burner. Each burner should light within four (4) seconds in normal operation after air has been purged from supply lines. Visually check that burner has lit. c. Once the burner lights, the control knob should be rotated out of the LITE position. There are separate ignition devices for each burner. Try each knob separately until all burner valves have been checked. 7 Figure 9