Electrical system requirements - washer

Page 4 highlights

4 Installation Requirements Electrical system requirements NOTE Because of potentially inconsistent voltage capabilities, the use of this dryer with power created by gas powered generators, solar powered generators, wind powered generators or any other generator other than the local utility company is not recommended. Electrical requirements for electric dryer: CIRCUIT - Individual 30 amp. branch circuit fused with 30 amp. time delay fuses or circuit breakers. Use separately fused circuits for washer and dryer. DO NOT operate a washer and a dryer on the same circuit. POWER SUPPLY - 3-wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current. IMPORTANT This dryer is internally grounded to neutral unless it was manufactured for sale in Canada. Only a 4-conductor cord shall be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral link is prohibited for: (1) new branch circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes do not permit grounding through the neutral. 3-WIRE POWER SUPPLY CORD KIT (not supplied) 3-wire receptacle (NEMA type 10-30R) The dryer MUST employ a 3-conductor power supply cord NEMA 10-30 type SRDT rated at 240 volt AC minimum, 30 amp, with 3 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers. For 3-wire cord connection instructions see ELECTRICAL CONNECTIONS FOR A 3-WIRE SYSTEM. 4-WIRE POWER SUPPLY CORD KIT (not supplied) 4-wire receptacle (NEMA type 14-30R) The dryer MUST employ a 4-conductor power supply cord NEMA 14-30 type SRDT or ST (as required) rated at 240 volt AC minimum, 30 amp, with 4 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers. For 4-wire cord connection instructions see ELECTRICAL CONNECTIONS FOR A 4-WIRE SYSTEM. NOTE Dryers manufactured for sale in Canada have factory-installed, 4-wire power supply cord (NEMA 14-30R). OUTLET RECEPTACLE - NEMA 10-30R or NEMA 14-30R receptacle to be located so the power supply cord is accessible when the dryer is in the installed position. GROUNDING CONNECTION - See "Grounding requirements" in Electrical Installation section. Electrical requirements for gas dryer: CIRCUIT - Individual, properly polarized and grounded 15 amp. branch circuit fused with 15 amp. time delay fuse or circuit breaker. POWER SUPPLY - 2-wire, with ground, 120 volt, single phase, 60 Hz, Alternating Current. POWER SUPPLY CORD - The dryer is equipped with a 120 volt 3-wire power cord. GROUNDING CONNECTION - See "Grounding requirements" in Electrical Installation section. Grounding type wall receptacle Do not, under any circumstances, cut, remove, or bypass the grounding prong. Power cord with 3-prong grounded plug

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

4
Installation Requirements
IMPORTANT
This dryer is internally grounded to neutral unless it
was manufactured for sale in Canada.
Only a 4-conductor cord shall be used when the
appliance is installed in a location where grounding
through the neutral conductor is prohibited.
Grounding through the neutral link is prohibited for:
(1) new branch circuit installations, (2) mobile homes,
(3) recreational vehicles, and (4) areas where local
codes do not permit grounding through the neutral.
NOTE
Dryers manufactured for sale in Canada have
factory-installed, 4-wire power supply cord
(NEMA 14-30R).
Electrical system requirements
Electrical requirements for electric dryer:
CIRCUIT - Individual 30 amp. branch circuit
fused with 30 amp. time delay fuses or circuit
breakers. Use separately fused circuits for
washer and dryer. DO NOT operate a washer
and a dryer on the same circuit.
POWER SUPPLY - 3-wire or 4-wire, 240 volt,
single phase, 60 Hz, Alternating Current.
3-WIRE POWER SUPPLY CORD KIT (not supplied)
OUTLET RECEPTACLE - NEMA 10-30R or NEMA
14-30R receptacle to be located so the power
supply cord is accessible when the dryer is in the
installed position.
GROUNDING CONNECTION - See “Grounding
requirements” in Electrical Installation section.
The dryer MUST employ a 3-conductor power
supply cord NEMA 10-30 type SRDT rated at
240 volt AC minimum, 30 amp, with 3 open
end spade lug connectors with upturned ends
or closed loop connectors and marked for use
4-WIRE POWER SUPPLY CORD KIT (not supplied)
The dryer MUST employ a 4-conductor power
supply cord NEMA 14-30 type SRDT or ST (as
required) rated at 240 volt AC minimum, 30 amp,
with 4 open end spade lug connectors with
upturned ends or closed loop connectors and
marked for use with clothes dryers. For 4-wire
cord connection instructions see ELECTRICAL
CONNECTIONS FOR A 4-WIRE SYSTEM.
Electrical requirements for gas dryer:
CIRCUIT -
Individual, properly polarized and
grounded 15 amp. branch circuit fused with 15
amp. time delay fuse or circuit breaker.
POWER SUPPLY - 2-wire, with ground, 120 volt,
single phase, 60 Hz, Alternating Current.
POWER SUPPLY CORD - The dryer is equipped
with a 120 volt 3-wire power cord.
GROUNDING CONNECTION - See “Grounding
requirements” in Electrical Installation section.
Grounding type
Grounding type
wa
wa
ll receptacl
ll receptacl
e
Po
Po
wer cord with
wer cord with
3-prong
3-prong
gr
gr
ounded plug
ounded plug
Do not,
Do not,
under
under
an
an
y cir
y cir
cumstances,
cumstances,
cut,
cut,
remo
remo
ve
ve
,
or b
or b
ypass th
ypass th
e
gr
gr
ounding pr
ounding pr
ong.
ong.
3-wire receptacle
(NEMA type 10-30R)
4-wire receptacle
(NEMA type 14-30R)
NOTE
Because of potentially inconsistent voltage capabilities, the use of this dryer with power created
by gas powered generators, solar powered generators, wind powered generators or any other
generator other than the local utility company is not recommended.
with clothes dryers. For 3-wire cord connection
instructions see ELECTRICAL CONNECTIONS
FOR A 3-WIRE SYSTEM.