Electrolux RH30WC55GS Complete Owner's Guide (English) - Page 11
Connecting the ductwork, Air deflector installation, Recir, Recirculating accessories, culating - dimensions
UPC - 012505558771
View all Electrolux RH30WC55GS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
11 Installing the hood • Remove the hood. • Drive "lower" wood screws, by hand. Remove screws. • Mount the hood onto the "upper" screws. • Drive and tighten the "upper" wood screws, by hand. • Drive and tighten the "lower" wood screws, by hand. Air deflector installation (Recirculating accessories) • Assemble the air deflector with the duct cover bracket with 4 assembly screws provided as shown. • Measure from the bottom of the air deflector to the bottom of the hood outlet, as shown. Connecting the ductwork • Install ductwork, making connections in the direction of airflow as illustrated. • Push duct over the exhaust outlet. • Wrap all duct joints and the flange connections with duct tape for an airtight seal. • Make the same connection in the wall or ceiling vent exit. Airflow Duct tape over seam Dimension to measure • Cut the duct at the measured size. • Uninstall the air deflector removing the 4 assembly screws. • Slip the duct onto the bottom of the deflector. • Place the assembled deflector and duct over the exhaust outlet from the hood. • Assemble the air deflector to the duct cover bracket with 4 assembly screws provided as shown.