Using The Thermostat, Defrosting
View all Emerson CR519BE- manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
NOTES: Temperature range of the chiller compartment is 30°F to 48°F at room temperature of 77°F (25°C). Ice cream and Popsicles must be kept cool at -5°F to 0°F, hence this chiller compartment is not suitable to store these types of items. USING THE THERMOSTAT The thermostat control for the refrigerator and chiller is located at the upper right hand corner of the chiller compartment. The first time you turn the unit on, adjust the thermostat control knob to 3 and give your refrigerator time to cool down completely before adding food; a full 24 hours is r ecommended. After it is fully cooled, test it and adjust towards 1 to make less cool or towards 6 to c ool more to best suit your needs. However, t he setting of 3 should be appropriate for h ome or office refrigerator use. NOTE: Turning the thermostat control knob to t he OFF position will stop the cooling cycle. DEFROSTING Chiller compartment: If the chiller has accumulated excessive frost/ice please do the following: 1. Turn the thermostat knob to the OFF position and leave the chiller door open. 2. Remove all food and ice cube tray or transfer to refrigerator compartment. 3. Place towel under compact refrigerator or move refrigerator outdoors where no water damage can occur. 4. Clean and wipe out the melted frost with a cloth. NOTE: To avoid damaging the chiller compartment wall, do not use any sharp objects to remove the frost or to separate the frozen food. 5