Page 1 highlights
EPSON AMERICA INC. Product Support Bulletin EPSON Subject: New ActionLaser 1000/1500 Imaging Cartridge Replacement Procedure Date: 6/4/93 Page(s): 1 of 2 PSB No: P-0100 Originator: LHT This bulletin provides supplemental information to resolve a situation when printed images become faint, SelecType Level 2 TONER message indicating that the toner amount is low (E* F), and three messages flash in rotation on the LCD: NEW CARTRIDGE? YES, PRESS RESET NO, PRESS CONTINUE. After the instructions to replace the imaging cartridge (as shown on pages 3-29 through 3-32 of the ActionLaser 1000/1500 Reference Guide) has been followed, some printers may continue to display the above messages. This condition does not affect printer operation or print quality in any way. It can be corrected by resetting the printer as described below: NOTE: Resetting clears all the saved SelecType information but the status sheet printed in step 3 shows the current settings. 1. Press the LEVEL 1 button to enter SelecType Level 1. 2. Press CONTINUE (v) button until STATUS SHEET appears on the display. 3. Press INITIALIZE / RESET (b) button twice to print a status sheet. 4. Save the status sheet for future reference, then turn off the printer. 5. Press and hold down the ON LINE, CONTINUE (v), and FEED (b) buttons while you turn on the printer and keep pressing the buttons until the following message appears: STARTUP ERROR LTA4 When the above message appears, release the buttons.