Epson DM-D500 Users Manual - Page 8

DIP Switches

Page 8 highlights

English DIP Switches The DIP switches configure the communication settings and whether a self-test is required. CAUTION: Do not remove the DIP switch cover until after turning the power off. Removing the cover while the power is turned on may damage the device. DSW 1 DSW1 No. Function ON OFF 1-1 Received Error Data Ignore "?" Display 1-2 Hand shaking XON/XOFF (*1) DTR/DSR 1-3 Receive Data Length 7bit 8bit 1-4 Parity With Parity No Parity 1-5 Parity Selection Even Odd 1-6 Communication Speed See "Transfer Speed Switching." 1-7 Switching 1-8 (*1) XON/XOFF is effective only when the DM-D500 is connected with a stand alone. Default Setting OFF OFF OFF OFF OFF ON OFF ON Transfer Speed Switching SW1-6 ON OFF ON OFF ON OFF ON SW1-67 ON ON OFF OFF ON ON OFF SW1-8 ON ON ON ON OFF OFF OFF Transfer Speed (bps) 2400 4800 9600 (Default) 19200 38400 57600 115200 DSW 2 DSW1 No. 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8 Function Y-connection (*1) Self test selection (*2) 20 column and 2 line mode selection (*3) Device selection default setting (*4) Address 0 Address 1 Address 2 Reserved (*5) ON OFF Enable Disable Perform self test Do not perform 20 column and 256 x 64 dots 2 line mode mode Printer is selected Display is selected The display device number (1-7) corresponds to Address number 0 to 2. (All OFF are regarded as no display number.) - Fixed to OFF Default Setting OFF OFF OFF OFF OFF OFF OFF OFF 4 DM-D500 User's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

4
DM-D500 User’s Manual
English
DIP Switches
The DIP switches configure the communication settings and whether a self-test is
required.
CAUTION:
Do not remove the DIP switch cover until after turning the power off. Removing
the cover while the power is turned on may damage the device.
DSW 1
(*1) XON/XOFF is effective only when the DM-D500 is connected with a stand alone.
Transfer Speed Switching
DSW 2
DSW1 No.
Function
ON
OFF
Default Setting
1-1
Received Error Data
Ignore
“?” Display
OFF
1-2
Hand shaking
XON/XOFF (*1)
DTR/DSR
OFF
1-3
Receive Data Length
7bit
8bit
OFF
1-4
Parity
With Parity
No Parity
OFF
1-5
Parity Selection
Even
Odd
OFF
1-6
Communication Speed
Switching
See “Transfer Speed Switching.”
ON
1-7
OFF
1-8
ON
SW1-6
SW1-67
SW1-8
Transfer Speed (bps)
ON
ON
ON
2400
OFF
ON
ON
4800
ON
OFF
ON
9600 (Default)
OFF
OFF
ON
19200
ON
ON
OFF
38400
OFF
ON
OFF
57600
ON
OFF
OFF
115200
DSW1 No.
Function
ON
OFF
Default Setting
2-1
Y-connection (*1)
Enable
Disable
OFF
2-2
Self test selection (*2)
Perform self test
Do not perform
OFF
2-3
20 column and 2 line
mode selection (*3)
20 column and
2 line mode
256 x 64 dots
mode
OFF
2-4
Device selection
default setting (*4)
Printer is
selected
Display is
selected
OFF
2-5
Address 0
The display device number
(1-7) corresponds to Address
number 0 to 2.
(All OFF are regarded as no display
number.)
OFF
2-6
Address 1
OFF
2-7
Address 2
OFF
2-8
Reserved (*5)
-
Fixed to OFF
OFF