Epson Expression 1600 Product Information Guide - Page 2

Electrical, Environmental, Safety Approvals, W with TPU or ADF - scanner

Page 2 highlights

EPSON Expression 1600 Digital halftoning AAS (Auto Area Segmentation, enable/ disable selectable) 3 halftoning modes (A, B, and C) and 4 dither patterns (A, B, C, and D) for bi-level and quad-level data 2 user-defined dither patterns (A, B) Gamma correction 2 types for CRT display 3 types for printer 1 type for user-defined Color correction 1 type for CRT display 3 types for printer output (available in color byte sequence mode and color line sequence mode) 1 type user-defined (only user-defined color correction is available for EPSON TWAIN Pro Interfaces Two SCSI 2 (Micro DB50 connectors) USB (Type B receptacle connector) Optional IEEE 1394 (FireWire) Light source White cold cathode fluorescent lamp (Xenon) Reliability MCBF 100,000 cycles of carriage movements (main unit) Dimensions Width: 13.0 inches (332 mm) Depth: 22.1 inches (562 mm) Height: 5.3 inches (134 mm) Weight Approx. 18.7 lb (8.5 kg) Electrical Input voltage range 100 to 200 VAC-90 to 132 VAC 220 to 240 VAC-198 to 264 VAC; autoswitching Rated frequency 50 to 60 Hz Rated current 100 to 120 VAC-0.8 A 220 to 240 VAC-0.4 A Power consumption Operating Approximately 30 W (approximately 50 W with TPU or ADF Standby Approximately 10 W (without TPU or ADF) Check the label on the back of the scanner for voltage information. Environmental Temperature Operating 41 to 95 °F (5 to 35 °C) Standby -13 to 140 °F (-25 to 60 °C) Humidity (without condensation) Operating 10% to 80% Standby 10% to 85% Operating conditions Ordinary office or home conditions; avoid dust, direct sunlight, or strong light. Be sure the outlet provides enough power. Safety Approvals 120 V Safety standards UL 1950 with D3 CSA C22.2 No. 950 with D3 EMC FCC part 15 subpart B class B (USA) CSA C108.8 class B (Canada) 230 V Safety standards EN 60950 (VDE) EMC EN 55022 (CISPR Pub 22) class B AS/NZS 3548 class B CE marking Low Voltage Directive 73/23/EEC EN60950 EMC Directive 89/336/EEC EN 55022 Class B EN 61000-3-2 EN 61000-3-3 EN 50082-1 IEC 801-2 IEC 801-3 IEC 801-4 3 - EPSON Expression 1600 1/00

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

EPSON Expression 1600
3 -
EPSON Expression 1600
1/00
Digital halftoning
AAS (Auto Area Segmentation, enable/
disable selectable)
3 halftoning modes (A, B, and C) and
4 dither patterns (A, B, C, and D) for
bi-level and quad-level data
2 user-defined dither patterns (A, B)
Gamma correction
2 types for CRT display
3 types for printer
1 type for user-defined
Color correction
1 type for CRT display
3 types for printer output (available in
color byte sequence mode and color line
sequence mode)
1 type user-defined (only user-defined
color correction is available for EPSON
TWAIN Pro
Interfaces
Two SCSI 2 (Micro DB50 connectors)
USB (Type B receptacle connector)
Optional IEEE 1394 (FireWire)
Light source
White cold cathode fluorescent lamp
(Xenon)
Reliability
MCBF 100,000 cycles of carriage
movements (main unit)
Dimensions
Width: 13.0 inches (332 mm)
Depth: 22.1 inches (562 mm)
Height: 5.3 inches (134 mm)
Weight
Approx. 18.7 lb (8.5 kg)
Electrical
Input voltage range 100 to 200 VAC—90 to 132 VAC
220 to 240 VAC—198 to 264 VAC;
autoswitching
Rated frequency
50 to 60 Hz
Rated current
100 to 120 VAC—0.8 A
220 to 240 VAC—0.4 A
Power
consumption
Operating
Approximately 30 W (approximately
50 W with TPU or ADF
Standby
Approximately 10 W (without TPU or
ADF)
Check the label on the back of the scanner for voltage information.
Environmental
Temperature
Operating
41 to 95 °F (5 to 35 °C)
Standby
–13 to 140 °F (–25 to 60 °C)
Humidity (without
condensation)
Operating
10% to 80%
Standby
10% to 85%
Operating
conditions
Ordinary office or home conditions; avoid
dust, direct sunlight, or strong light. Be sure
the outlet provides enough power.
Safety Approvals
120 V
Safety standards
UL 1950 with D3
CSA C22.2 No. 950 with D3
EMC
FCC part 15 subpart B class B
(USA)
CSA C108.8 class B (Canada)
230 V
Safety standards
EN 60950 (VDE)
EMC
EN 55022 (CISPR Pub 22) class B
AS/NZS 3548 class B
CE marking
Low Voltage
Directive
73/23/EEC
EN60950
EMC Directive
89/336/EEC
EN 55022 Class B
EN 61000-3-2
EN 61000-3-3
EN 50082-1
IEC 801-2
IEC 801-3
IEC 801-4