Environmental, Safety Approvals, USB Interface, EN 55022 CISPR Pub 22 class B - scanner

Page 2 highlights

EPSON Perfection 1200 Digital halftoning AAS (Auto Area Segmentation, enable/ disable selectable) 3 halftoning modes (A, B, and C) 4 dither patterns (A, B, C, and D) for bi-level and quad-level data 2 user defined patterns (A and B) Gamma correction 2 types for CRT display 3 types for printer 1 type for user-defined Color correction 1 type for CRT display 3 types for printer output (available in color byte sequence mode and color line sequence mode) 1 type for user-defined Interface USB (1200U, 1200U PHOTO: Type B receptacle connector) SCSI (1200S: Two half pitch 50-pin connectors) Light source White cold cathode fluorescent lamp Reliability 30,000 cycles of carriage movements (main unit MCBF) Dimensions Width: 11.3 inches (287 mm) Depth: 16.7 inches (425 mm) Height: 3.4 inches (88 mm) Weight Approx. 9.9 lb (4.5 kg) Electrical Specification Input voltage range Rated frequency Input frequency Rated current Power consumption 100−120 V model 220−240 V model AC 90 to 132 V AC 198 to 264 V 50 to 60 Hz 49.5 to 60.5 Hz 0.5 A 0.3 A Approx. 25 W operating Approx. 12 W stand by Note: Check the label on the back of the scanner for voltage information. Environmental Temperature Humidity (without condensation) Operation: 41 to 95 °F (5 to 35 °C); 50 to 90 °F (10 to 32 °C) when using the auto document feeder Storage: –13 to 140 °F (–25 to 60 °C) Operation: 10% to 80%; 20% to 80% when using the auto document feeder Storage: 10% to 85% Operating conditions Ordinary office or home conditions; avoid extreme dust, direct sunlight, and strong light sources. Make sure the outlet provides enough power. Safety Approvals 120 V model Safety standards UL 1950 with D3 CSA C22.2 No. 950 EMC FCC part 15 subpart B class B CSA C108.8 class B 230 V model Safety standards EN 60950 EMC EN 55022 (CISPR Pub 22) class B AS/NZS 3548 class B CE marking 230 V model Low Voltage Directive 73/23/EEC EN 60950 EMC Directive 89/336/EEC EN 55022 Class B EN 61000-3-2 EN 61000-3-3 EN 50082-1 IEC 801-2 IEC 801-3 IEC 801-4 USB Interface Interface type Configuration Universal Serial Bus Specification Revision 1.0 Element Configuration Interface Endpoint 1 Endpoint 2 String Descriptor Description Characteristics: Self-powered Remote wake up feature: Not supported Maximum power consumption from VBUS: 2mA (5V) No alternate setting Number of endpoints used by this interface (excluding endpoint 0): 2 Class: Vendor specific Bulk IN transfer Maximum data transfer size: 64 byte Bulk OUT transfer Maximum data transfer size: 64 byte Language ID: US English 1: iManufacturer: “EPSON” 2: iProduct: “Perfection1200” 2 - EPSON Perfection 1200 8/99

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

EPSON Perfection 1200
2 -
EPSON Perfection 1200
8/99
Digital halftoning
AAS (Auto Area Segmentation, enable/
disable selectable)
3 halftoning modes (A, B, and C)
4 dither patterns (A, B, C, and D) for
bi-level and quad-level data
2 user defined patterns (A and B)
Gamma correction
2 types for CRT display
3 types for printer
1 type for user-defined
Color correction
1 type for CRT display
3 types for printer output (available in
color byte sequence mode and color line
sequence mode)
1 type for user-defined
Interface
USB (1200U, 1200U PHOTO: Type B
receptacle connector)
SCSI (1200S: Two half pitch 50-pin
connectors)
Light source
White cold cathode fluorescent lamp
Reliability
30,000 cycles of carriage movements
(main unit MCBF)
Dimensions
Width: 11.3 inches (287 mm)
Depth: 16.7 inches (425 mm)
Height: 3.4 inches (88 mm)
Weight
Approx. 9.9 lb (4.5 kg)
Electrical
Note:
Check the label on the back of the scanner for voltage
information.
Environmental
Temperature
Operation: 41 to 95 °F (5 to 35 °C);
50 to 90 °F (10 to 32 °C) when using the
auto document feeder
Storage: ±13 to 140 °F (±25 to 60 °C)
Humidity
Operation: 10% to 80%; 20% to 80%
(without
when using the auto document feeder
condensation)
Storage: 10% to 85%
Operating
Ordinary office or home conditions; avoid
conditions
extreme dust, direct sunlight, and strong
light sources. Make sure the outlet
provides enough power.
Safety Approvals
120 V model
Safety standards
UL 1950 with D3
CSA C22.2 No. 950
EMC
FCC part 15 subpart B class B
CSA C108.8 class B
230 V model
Safety standards
EN 60950
EMC
EN 55022 (CISPR Pub 22) class B
AS/NZS 3548 class B
CE marking
230 V model
Low Voltage Directive 73/23/EEC
EN 60950
EMC Directive 89/336/EEC
EN 55022 Class B
EN 61000-3-2
EN 61000-3-3
EN 50082-1
IEC 801-2
IEC 801-3
IEC 801-4
USB Interface
Interface type
Universal Serial Bus Specification
Revision 1.0
Configuration
Specification
100
-
120 V model
220
-
240 V model
Input voltage range
AC 90 to 132 V
AC 198 to 264 V
Rated frequency
50 to 60 Hz
Input frequency
49.5 to 60.5 Hz
Rated current
0.5 A
0.3 A
Power consumption
Approx. 25 W operating
Approx. 12 W stand by
Element
Description
Configuration
Characteristics: Self-powered
Remote wake up feature: Not supported
Maximum power consumption from VBUS:
2mA (5V)
Interface
No alternate setting
Number of endpoints used by this interface
(excluding endpoint 0): 2
Class: Vendor specific
Endpoint 1
Bulk IN transfer
Maximum data transfer size: 64 byte
Endpoint 2
Bulk OUT transfer
Maximum data transfer size: 64 byte
String Descriptor
Language ID: US English
1: iManufacturer: ²EPSON³