Epson TM-H6000IV-DT ePOS-Device XML Users Manual - Page 68

Message Data for Device Hub Terminal, <type>shutdown</type>, <type>onshutdown</type

Page 68 highlights

Message Data for Device Hub Terminal • Cannot be used with TM-i Series. • Available with ePOS-Device Ver.2.5 or later. • If sending this message data, use EPSON TMNet WebConfig to perform shutdown settings for the TM-DT.  ([Settings]-[System settings]-[Shutdown settings]-[ePOS-Device]) shutdown Request Shuts down the power source of the device hub terminal (TM-DT). Sub-element Data type password string Description Specifies the password for EPSON TMNet WebConfig. ❏ Example local_dt shutdown epson onshutdown Response Returns the shutdown results of the device hub terminal (TM-DT) to the application. Sub-element Data type status string Description Result of the sent data. For details, refer to the status below. ❏ status Element value "SUCCESS" "AUTHENTICATION_ERROR" "ACCESS_DENIED" "SYSTEM_ERROR" Description Shutdown successfully completed Password authentication error Shutdown from ePOS-Device XML is not set System error occurred 68

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218

68
Message Data for Device Hub Terminal
<type>shutdown</type>
Request
Shuts down the power source of the device hub terminal (TM-DT).
Example
<type>onshutdown</type>
Response
Returns the shutdown results of the device hub terminal (TM-DT) to the application.
status
Cannot be used with TM-i Series.
Available with ePOS-Device Ver.2.5 or later.
If sending this message data, use EPSON TMNet WebConfig to perform shutdown
settings for the TM-DT.
([Settings]-[System settings]-[Shutdown settings]-[ePOS-Device])
Sub-element
Data type
Description
password
string
Specifies the password for EPSON TMNet WebConfig.
Sub-element
Data type
Description
status
string
Result of the sent data.
For details, refer to the status below.
Element value
Description
“SUCCESS”
Shutdown successfully completed
“AUTHENTICATION_ERROR”
Password authentication error
“ACCESS_DENIED”
Shutdown from ePOS-Device XML is not set
“SYSTEM_ERROR”
System error occurred
<device_data>
<device_id>local_dt</device_id>
<data>
<type>shutdown</type>
<password>epson</password>
</data>
</device_data>