Epson TM-T20II-i TM-i WebConfig API Users Manual For TM-i firmware ver.4.1 - Page 44
Setting a Serial Communication Device, SettingUrl : set_epos_serial.cgi
View all Epson TM-T20II-i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
Setting a Serial Communication Device SettingUrl : set_epos_serial.cgi Changes the communication settings of the serial communication device, and device ID sets to [local_serilal]. If the TM-i specifications include no serial ports, this setting is disabled. POST parameter Use Baudrate Databit Parity Stopbit FlowControl Specifiable value Enable Disable 2400 4800 9600 19200 38400 57600 115200 7 8 None Even Odd 1 1.5 2 XOnXOff Hardware None Description Designates whether to use a serial communication device. Enable Disable Specifies the communication speed. 2400 bps 4800 bps 9600 bps 19200 bps 38400 bps 57600 bps 115200 bps Specifies the data bit. 7 bits 8 bits Specifies the parity. None Even Odd Specifies the stop bit. 1 bit 1.5 bit 2 bit Specifies the flow control. XOnXOff Hardware None 44