Epson TM U295 User Manual - Page 43

Attention in use. - cables

Page 43 highlights

7.Attention in use. 1) When you connect the printer over the serial (COM) port, be sure to set the flow control to Xon/Xoff. In the cases below, however, please set the hardware control on OS side and set TM printer to DTR/DSR. * When using EPSON DM-D10x, 20x Printer Driver • TM Printer Driver's settings when connecting TM printer via DM-D customer display. Also, please use the following cables to connect between PC and DM-D customer display(DM-D101/DM- D105/DM-D205). "The available cables diagram" Printer side User side D-sub25 Connector Signal name Pin Number Signal name D-sub25 Connector Pin Number 8 (NC) DCD 1 3 RxD RxD 2 2 TxD TxD 3 20 DTR DTR 4 7 SG SG 5 6 DSR DSR 6 4 RTS RTS 7 5 CTS CTS 8 22 (NC) RI 9 Furthermore, though the cables on the market have the one that is listed in the following wiring structure, its type can not be used. "The unavailable cables diagram" Printer side User side D-sub25 Connector Signal name Pin Number Signal name D-sub25 Connector Pin Number 8 (NC) DCD 1 3 RxD RxD 2 2 TxD TxD 3 20 DTR DTR 4 7 SG SG 5 6 DSR DSR 6 4 RTS RTS 7 5 CTS CTS 8 22 (NC) RI 9 TITLE EPSON TM Printer Driver User's Manual SHEET REVISION 1.60 NO NEXT 44 SHEET 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45

TITLE
TM Printer Driver
SHEET
REVISION
NO
User's Manual
1.60
NEXT
44
SHEET
43
EPSON
7.Attention in use.
1)
When you connect the printer over the serial (COM) port, be sure to set the flow control to Xon/Xoff. In the cases
below, however, please set the hardware control on OS side and set TM printer to DTR/DSR.
* When using EPSON DM-D10x, 20x Printer Driver
TM Printer Driver's settings when connecting TM printer via DM-D customer display.
Also, please use the following cables to connect between PC and DM-D customer display(DM-D101/DM-
D105/DM-D205).
"The available cables diagram"
Printer side
User side
D-sub25 Connector
Pin Number
Signal name
Signal name
D-sub25 Connector Pin
Number
8
(NC)
DCD
1
3
RxD
RxD
2
2
TxD
TxD
3
20
DTR
DTR
4
7
SG
SG
5
6
DSR
DSR
6
4
RTS
RTS
7
5
CTS
CTS
8
22
(NC)
RI
9
Furthermore, though the cables on the market have the one that is listed in the following wiring structure, its type
can not be used.
"The unavailable cables diagram"
Printer side
User side
D-sub25 Connector
Pin Number
Signal name
Signal name
D-sub25 Connector Pin
Number
8
(NC)
DCD
1
3
RxD
RxD
2
2
TxD
TxD
3
20
DTR
DTR
4
7
SG
SG
5
6
DSR
DSR
6
4
RTS
RTS
7
5
CTS
CTS
8
22
(NC)
RI
9