3-Wire Connections plus separate grounding connector For use where local codes do not permit grounding through the Neutral wire. Use approved 3-wire Power Supply Cord or a 3-wire Cable for Direct Wiring as described on page 25. A separate 10AWG copper grounding wire is required. 1 Remove the terminal block cover plate. 2 Insert the power supply cable with a UL listed strain relief through the hole provided in the cabinet near the terminal block. Do not tighten strain relief screw until wiring connections are complete. Note: a strain relief must be used. 2 strain relief clamp sections strain relief screws 3 Remove center terminal block screw. 4 Remove appliance ground link by removing the ground connector screw (Green screw). 5 Connect a separate copper ground wire (green with yellow stripe) using the ground connector screw (Green screw). Make sure a ring terminal is used when connecting the ground wire and that the wire is firmly secured to an adequate grounding path. 3 7 Note: If the appliance is 6 4 moved back to a 3-wire 5 installation the ground link must be refitted. Remove link 7 6 Connect the neutral wire (center) of the power supply cord to the center terminal screw of the terminal block. Tighten screw. 7 Connect the other wires to the upper and lower terminal block screws marked with the letter L. Tighten screws. 8 Refit terminal block cover by inserting the two tabs first on the rear panel of the dryer and secure cover with securing screw. 9 Tighten strain relief screws. 8 9 grounding wire It is recommended that a qualified electrician determine that the ground path is adequate 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

27
3-Wire Connections
plus separate grounding connector
For use where local codes
do not permit
grounding through the Neutral wire.
Use approved 3-wire Power Supply Cord or a 3-wire Cable for Direct Wiring as described on page 25.
A separate 10AWG copper grounding wire is required.
1
Remove the terminal block cover plate.
2
Insert the power supply cable with a UL listed strain relief through the hole provided in the cabinet
near the terminal block. Do not tighten strain relief screw until wiring connections are complete.
Note:
a strain relief must be used.
2
strain relief
clamp sections
strain relief
screws
3
Remove center terminal block screw.
4
Remove appliance ground link by removing the ground connector screw (Green screw).
5
Connect a separate copper ground wire (green with yellow stripe) using the ground connector
screw (Green screw). Make sure a ring terminal is used when connecting the ground wire and that
the wire is firmly secured to an adequate grounding path.
3
4
7
6
5
7
Note: If the appliance is
moved back to a 3-wire
installation the ground
link must be refitted.
Remove link
6
Connect the neutral wire (center) of the power supply cord to the center terminal screw of the
terminal block. Tighten screw.
7
Connect the other wires to the upper and lower terminal block screws marked with the
letter L. Tighten screws.
8
Refit terminal block cover by inserting the two tabs first on the rear panel of the dryer and secure
cover with securing screw.
9
Tighten strain relief screws.
It is recommended that a qualified electrician
determine that the ground path is adequate
grounding wire
8
9