Fisher and Paykel OR36SDBGX2 OR36SDGBX Installation (English, French) - Page 20
Operations To Be, Performed When, Substituting The, Injectors, Injectors Table
View all Fisher and Paykel OR36SDBGX2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
b2 INJECTORS TABLE BURNERS NOMINAL POWER BTU/hr REDUCED POWER BTU/hr Semi-rapid (R) 6000 1500 Triple ring (TC) 12000 5000 Dual (D) Inner crown Outer crowns 2800 for NATURAL GAS (*) 3500 for LP/PROPANE GAS (*) 1000 (*) 16000 for NATURAL GAS (#) 6500 for NATURAL GAS (#) 15000 for LP/PROPANE GAS (#) 4500 for LP/PROPANE GAS (#) Oven burner 21000 2700 Broil burner 15000 - LP/PROPANE 11" W.C.P. Ø injector [1/100 mm] 72 102 55 (no. 1 central) 72 (no. 2 outer) 135 115 (*) Power calculated only with inner crown operating (#) Power calculated with inner and outer crowns operating NATURAL GAS 4" W.C.P. Ø injector [1/100 mm] 118 170 80 (no. 1 central) 130 (no. 2 outer) 247 200 Semi-rapid burner Fig. 2.6a DUAL burner J Injectors for outer crowns Triple ring burner J Fig. 2.6b OPERATIONS TO BE PERFORMED WHEN SUBSTITUTING THE J INJECTORS ✓ Remove the gratings and the burner covers; ✓ Using a wrench substitute the nozzle injectors "J" (figs. 2.6a - 2.6b - 2.6c) with those most suitable for the kind of gas for which it is to be used. The burner are conceived in such a way so as not to require the regulation of the primary air. J Injector for inner crown Fig. 2.6c 20