Fisher and Paykel OR36SDBMX1 Installation Manual - Page 25

Adjustment Of The Oven Burner Minimum

Page 25 highlights

2 ADJUSTMENT OF THE OVEN BURNER MINIMUM This needs to be done only for the oven burner (the broil is a fixed capacity) by acting on the thermostat in the following way: • Turn on the burner by setting the thermostat knob on position "8" (maximum). • Remove the knob and unscrew the by-pass screw "G" (fig. 2.19) about three times by passing a small flat screwdriver (Ø 3 mm blade, 100 mm length) through the panel opening. • Re-mount the knob and let the oven heat up for about 10 minutes, then bring the knob to position "1" (minimum) to operate the thermostat by-pass. • After having removed the knob again and being very careful not to turn the thermostat stem, slowly screw the by-pass screws "G" (fig. 2.19) until you obtain a flame of 3-4 mm in height. The flame should not go out even when passing suddenly from maximum to minimum flame. For LP/Propane gas, tighten the by-pass screw completely. Fig. 2.19 G After regulation repeat the operations indicated in paragraph "2. PRESSURE REGULATOR" at page 12 and 17. If the range has been disconnected and then connected again to the gas supply line repeat the operations indicated in paragraph "5. LEAK TESTING" at page 17. IMPORTANT: • After conversion to LP/PROPANE gas has been carried out affix near the data plate the conversion label supplied and also affix a conversion label at page 3 of this instruction manual. • After conversion back to the original gas (NATURAL GAS) has been carried out remove, near the data plate and at page 3 of this instruction manual, the LP/PROPANE conversion labels. Save the labels removed for future use. 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

25
25
2
ADJUSTMENT OF THE OVEN BURNER MINIMUM
This needs to be done only for the oven burner (the broil is a
xed capacity) by acting
on the thermostat in the following way:
Turn on the burner by setting the thermostat knob on position “
8
” (maximum).
Remove the knob and unscrew the by-pass screw “
G
” (
g. 2.19) about three times by
passing a small
at screwdriver (Ø 3 mm blade, 100 mm length) through the panel
opening.
Re-mount the knob and let the oven heat up for about 10 minutes, then bring the knob
to position “
1
” (minimum) to operate the thermostat by-pass.
After having removed the knob again and being very careful not to turn the thermostat
stem, slowly screw the by-pass screws “
G
” (
g. 2.19) until you obtain a
ame of 3-4
mm in height. The
ame should not go out even when passing suddenly from maxi-
mum to minimum
ame.
For LP/Propane gas, tighten the by-pass screw completely.
After regulation repeat the operations indicated in paragraph “2. PRESSURE REGULA-
TOR” at page 12 and 17.
If the range has been disconnected and then connected again to the gas supply line repe-
at the operations indicated in paragraph “5. LEAK TESTING” at page 17.
IMPORTANT:
After conversion to LP/PROPANE gas has been carried out af
x near the data plate
the conversion label supplied and also af
x a conversion label at page 3 of this in-
struction manual.
After conversion back to the original gas (NATURAL GAS) has been carried out re-
move, near the data plate and at page 3 of this instruction manual, the LP/PROPANE
conversion labels. Save the labels removed for future use.
Fig. 2.19
G