Page 17 highlights

9 ATTACH ANTI-TIP BRACKET IMPORTANT! Safety requires refrigerators be stable when doors and/or drawer, are open. An anti-tip bracket and fittings supplied must be fitted to the wall of the finished enclosure to withstand a 220.5 pound (100 kg) load. This will prevent the possibility of the appliance tipping forward, when doors and/or drawer, are open. When fastening with masonry plugs and/or screws: ●● Ensure the screws avoid electrical, gas and water conduits. ●● Ensure the surface the bracket is fastened to withstand a 220.5 pound (100 kg) load. ●● Ensure light-weight masonry material such as cinder block and new concrete (no curing time) are not used in installation. ●● Do not use metallic materials that may corrode, stain and/or damage the enclosure. WOODEN/PLASTER BOARD WALL INSTALLATION SOLID WALL INSTALLATION SPACER INSTALLATION 1 Project the end of the above finished enclosure to the center of the back wall and subtract 1 ¼" (31 mm). This will locate the contact surface between the bracket and the appliance (refer to A). Ensure a structural beam/wall stud closest to the center of the wall enclosure is located. 1 Project the end of the above finished enclosure to the center of the back wall and subtract 1 ¼" (31 mm). This will locate the contact surface between the bracket and the appliance (refer to A). If a minimum 2 3/8" (60 mm) overlap cannot be achieved we recommend fastening a solid spacer (wooden beam etc) behind the bracket. 1 Ensure the length of the spacer corresponds to the enclosure's width. Always secure the spacer to existing studs on the enclosure wall (refer to C). 1 1/4" (31 mm) 2 3/8" min. (60 mm) overlap A Bracket PROFILE VIEW 2 Fix bracket to the wall with screws x4 (#10 x 40 pan head Phillips screw). Ensure screws hold tight and the bracket overlaps the appliance when it is positioned (2 3/8" min. (60 mm)) for a secure hold. 1 1/4" (31 mm) 2 3/8" min. (60 mm) overlap PROFILE VIEW A Bracket 1 1/4" (31 mm) 2 3/8" min. (60 mm) overlap Spacer C Bracket PROFILE VIEW 2 Mark screw locations to drill Ø ¼" x 1 ⅜" (Ø6.0 mm x 35 mm) deep holes. Hammer masonry plugs into the wall until flush x4. Fix bracket to the wall with screws x4 (#10 x 40 pan head Phillips screws). Ensure screws hold tight. 2 Fix bracket to the spacer with screws x4 (#10 x 40 pan head Phillips screws). Ensure screws hold tight and the bracket overlaps the appliance when it is positioned (2 3/8" min. (60 mm)) for a secure hold. 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

15
9
ATTACH ANTI-TIP BRACKET
IMPORTANT!
Safety requires refrigerators be stable when doors and/or drawer, are open. An anti-tip bracket and fittings supplied must be fitted to the wall of the finished enclosure to withstand
a 220.5 pound (100 kg) load. This will prevent the possibility of the appliance tipping forward, when doors and/or drawer, are open.
When fastening with masonry plugs and/or screws:
±
Ensure the screws avoid electrical, gas and water conduits.
±
Ensure the surface the bracket is fastened to withstand a 220.5 pound (100 kg) load.
±
Ensure light-weight masonry material such as cinder block and new concrete (no curing time) are not used in installation.
±
Do not use metallic materials that may corrode, stain and/or damage the enclosure.
If a minimum 2 Á” (60 mm) overlap cannot be achieved
we recommend fastening a solid spacer (wooden beam etc)
behind the bracket.
1
Ensure the length of the spacer corresponds to the
enclosure’s width. Always secure the spacer to existing
studs on the enclosure wall (refer to
C
).
2
Fix bracket to the wall with screws x4 (#10 x 40 pan head
Phillips screw). Ensure screws hold tight and the bracket
overlaps the appliance when it is positioned (2 Á” min.
(60 mm)) for a secure hold.
WOODEN/PLASTER BOARD
WALL INSTALLATION
SOLID WALL INSTALLATION
1
Project the end of the above finished enclosure to the
center of the back wall and subtract 1 °” (31 mm). This
will locate the contact surface between the bracket and
the appliance (refer to
A
).
2
Fix bracket to the spacer with screws x4 (#10 x 40 pan
head Phillips screws). Ensure screws hold tight and the
bracket overlaps the appliance when it is positioned
(2 Á” min. (60 mm)) for a secure hold.
1
Project the end of the above finished enclosure to the
center of the back wall and subtract 1 °” (31 mm). This
will locate the contact surface between the bracket and
the appliance (refer to
A
).
Ensure a structural beam/wall stud closest to the center
of the wall enclosure is located.
SPACER INSTALLATION
2
Mark screw locations to drill Ø °” x 1 Á” (Ø6.0 mm x 35 mm)
deep holes. Hammer masonry plugs into the wall until flush
x4. Fix bracket to the wall with screws x4 (#10 x 40 pan
head Phillips screws). Ensure screws hold tight.
A
2 Á” min.
(60 mm)
overlap
Bracket
PROFILE VIEW
1 °” (31 mm)
C
2 Á” min.
(60 mm)
overlap
Bracket
PROFILE VIEW
1 °” (31 mm)
Spacer
A
2 Á” min.
(60 mm)
overlap
Bracket
PROFILE VIEW
1 °” (31 mm)