Fluke 116 Fluke 116 Digital Multimeter Datasheet - Page 1

Fluke 116 Manual

Page 1 highlights

Fluke 116 HVAC Multimeter with Temperature and Microamps Technical Data Actual size R N10140 Compact true-rms meter for HVAC troubleshooting The Fluke 116 was specifically designed for the HVAC professional. It has everything needed in an HVAC meter including temperature and microamp measurements to quickly troubleshoot problems with HVAC equipment and flame sensors. Features include: • Built in thermometer for HVAC applications • Microamps to test flame sensors • LoZ: helps prevent false readings due to ghost voltage • Large white LED backlight to work in poorly lit areas • Resistance, continuity, frequency and capacitance • Min/Max/Average with elapsed time to record signal fluctuations • Compact ergonomic design for one-handed operation • Compatible with optional magnetic hanger (ToolPak™) • CAT III 600 V safety rated General specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 95 %. The accuracy specifications take the form of: ± ( [ % of reading ] + [ counts ] ) Maximum voltage between any terminal and earth ground Surge protection Display Bar graph Operating temperature Storage temperature Battery Battery life 600 V 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Digital: 6,000 counts, updates 4/sec 33 segments, updates 32/sec -10 °C to + 50 °C -40 °C to + 60 °C 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 400 hours typical, without backlight

  • 1
  • 2

Technical Data
Fluke 116
HVAC Multimeter
with Temperature and Microamps
Features include:
Built in thermometer for HVAC applications
Microamps to test flame sensors
LoZ: helps prevent false readings due to ghost voltage
Large white LED backlight to work in poorly lit areas
Resistance, continuity, frequency and capacitance
Min/Max/Average with elapsed time to record signal
fluctuations
Compact ergonomic design for one-handed operation
Compatible with optional magnetic hanger (ToolPak
)
CAT III 600 V safety rated
Compact true-rms meter for
HVAC troubleshooting
The Fluke 116 was specifically designed
for the HVAC professional. It has every-
thing needed in an HVAC meter including
temperature and microamp measure-
ments to quickly troubleshoot problems
with HVAC equipment and flame sensors.
General specifications
Accuracy is specified for 1 year after calibration, at operating
temperatures of 18 °C to 28 °C, with relative humidity at
0 % to 95 %.
The accuracy specifications take the form of:
± ( [ % of reading ] + [ counts ] )
Maximum voltage between any
terminal and earth ground
600 V
Surge protection
6 kV peak per IEC 61010-1 600 V
CAT III, Pollution Degree 2
Display
Digital: 6,000 counts, updates 4/sec
Bar graph
33 segments, updates 32/sec
Operating temperature
-10 °C to + 50 °C
Storage temperature
-40 °C to + 60 °C
Battery
9 volt Alkaline, NEDA 1604A/
IEC 6LR61
Battery life
400 hours typical, without backlight
N10140
R
Actual size