Fluke 116 Fluke 116 Digital Multimeter Datasheet - Page 2

Accuracy specifications - meter

Page 2 highlights

Accuracy specifications Measurement DC millivolts DC volts Auto volts Range 600.0 mV 6.000 V 60.00 V 600.0 V 600.0 V Resolution 0.1 mV 0.001 V 0.01 V 0.1 V 0.1 V AC millivolts1 true-rms 600.0 mV AC volts1 true-rms 6.000 V 60.00 V 600.0 V Continuity 600 Ω 0.1 mV 0.001 V 0.01 V 0.1 V 1 Ω Ohms Diode test Capacitance Lo-Z capacitance Temperature2 (Type-K thermocouple) 600.0 Ω 6.000 kΩ 60.00 kΩ 600.0 kΩ 6.000 MΩ 40.00 MΩ 2.000 V 1000 nF 10.00 µF 100.0 µF 9999 µF 100 µF to 1000 µF > 1000 µF 1 nF to 500 µF -40 °C to 400 °C 0.1Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ 0.001 V 1 nF 0.01 µF 0.1 µF 1 µF 0.1 °C -40 °F to 752 °F 0.2 °F Accuracy ± ([% of reading] + [counts]) 2.0 % + 3 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) 1.0 % + 3 (45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) Beeper on < 20 Ω off > 250 Ω; detects opens or shorts of 500 µs or longer. 0.9 % + 2 0.9 % + 1 1.5 % + 2 0.9 % + 2 1.9 % + 2 1.9 % + 2 5 % + 20 10 % + 2 typical 1 % + 102 1 % + 182 Ordering information Fluke-116 HVAC Multimeter with Temperature and Microamps Included TL75 Test Leads, 80BK Integrated Temperature Probe, holster, User's manual and 9V battery (installed). AC µamps true-rms (45 Hz to 500 Hz) 600.0 µA 0.1 µA 1.5 % + 3 (2.5 % + 3 > 500 Hz) DC µamps 600.0 µA 0.1 µA 1.0 % + 2 Hz (V or A input)3 99.99 Hz 0.01 Hz 999.9 Hz 9.999 kHz 0.1 Hz 0.001 kHz 0.1 % + 2 50.00 kHz 0.01 kHz Notes: 1 All ac voltage ranges are specified from 1 % to 100 % of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled. 2 Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3 Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.  Fluke Corporation 116 HVAC Multimeter with Temperature and Microamps Fluke. Keeping your world up and running. Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 8/2006 2634037 D-EN-N Rev A

  • 1
  • 2

Accuracy specifications
2 Fluke Corporation
116 HVAC Multimeter with Temperature and Microamps
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa (31 40) 2 675 200 or
Fax (31 40) 2 675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
©2006 Fluke Corporation. All rights reserved.
Printed in U.S.A. 8/2006 2634037 D-EN-N Rev A
Fluke.
Keeping your world
up and running.
Measurement
Range
Resolution
Accuracy
± ([% of reading] + [counts])
DC millivolts
600.0 mV
0.1 mV
2.0 % + 3
DC volts
6.000 V
0.001 V
60.00 V
0.01 V
600.0 V
0.1 V
Auto volts
600.0 V
0.1 V
2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts
1
true-rms
600.0 mV
0.1 mV
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts
1
true-rms
6.000 V
0.001 V
1.0 % + 3 (45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
60.00 V
0.01 V
600.0 V
0.1 V
Continuity
600
Ω
1
Ω
Beeper on < 20
Ω
off > 250
Ω
; detects
opens or shorts of 500 µs or longer.
Ohms
600.0
Ω
0.1
Ω
0.9 % + 2
6.000 k
Ω
0.001 k
Ω
0.9 % + 1
60.00 k
Ω
0.01 k
Ω
600.0 k
Ω
0.1 k
Ω
6.000 M
Ω
0.001 M
Ω
40.00 M
Ω
0.01 M
Ω
1.5 % + 2
Diode test
2.000 V
0.001 V
0.9 % + 2
Capacitance
1000 nF
1 nF
1.9 % + 2
10.00 µF
0.01 µF
100.0 µF
0.1 µF
9999 µF
1 µF
100 µF to 1000 µF
1.9 % + 2
> 1000 µF
5 % + 20
Lo-Z capacitance
1 nF to 500 µF
10 % + 2 typical
Temperature
2
(Type-K
thermocouple)
-40 °C to 400 °C
0.1 °C
1 % + 10
2
-40 °F to 752 °F
0.2 °F
1 % + 18
2
AC µamps
true-rms
(45 Hz to 500 Hz)
600.0 µA
0.1 µA
1.5 % + 3 (2.5 % + 3 > 500 Hz)
DC µamps
600.0 µA
0.1 µA
1.0 % + 2
Hz (V or A input)
3
99.99 Hz
0.01 Hz
0.1 % + 2
999.9 Hz
0.1 Hz
9.999 kHz
0.001 kHz
50.00 kHz
0.01 kHz
Notes:
1
All ac voltage ranges are specified from 1 % to 100 % of range. Because inputs below 1 % of range are not specified,
it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected
from a circuit or are shorted together. For volts, crest factor of
3 at 4000 counts, decreasing linearly to 1.5 at full
scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.
2
Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3
Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
Ordering
information
Fluke-116
HVAC Multimeter
with Temperature
and Microamps
Included
TL75 Test Leads, 80BK Integrated
Temperature Probe, holster, User’s