Fluke 116 Fluke 116 Users Manual - Page 22

Table 1 Accuracy Specifications cont., Function, Range, Resolution, Accuracy, Continuity

Page 22 highlights

116 Users Manual Function Continuity Ohms Diode test Capacitance Lo-Z Capacitance Temperature (Type K Thermocouple) Table 1 Accuracy Specifications (cont.) Range 600 Ω 600.0 Ω 6.000 kΩ 60.00 kΩ 600.0 kΩ 6.000 MΩ 40.00 MΩ 2.000 V Resolution 1 Ω 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ 0.001 V Accuracy ± ([% of Reading] + [Counts]) Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. 0.9 % + 2 0.9 % + 1 0.9 % + 1 0.9 % + 1 0.9 % + 1 5 % + 2 0.9 % + 2 1000 nF 10.00 μF 100.0 μF 9999 μF 1 nF 0.01 μF 0.1 μF 1 μF 1 nF to 500 μF -40 ºC to 400 ºC 0.1 ºC -40 ºF to 752 ºF 0.2 ºF 1.9 % + 2 1.9 % + 2 1.9 % + 2 100 μF - 1000 μF: 1.9 % + 2 > 1000 μF: 5 % + 20 10% + 2 typical 1 % + 10[2] 1 % + 18[2] 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

116
Users Manual
20
Table 1 Accuracy Specifications (cont.)
Function
Range
Resolution
Accuracy
±
([% of Reading] + [Counts])
Continuity
600
Ω
1
Ω
Beeper on < 20
Ω
, off > 250
Ω
;
detects opens or shorts of
500
μ
s or longer.
Ohms
600.0
Ω
6.000 k
Ω
60.00 k
Ω
600.0 k
Ω
6.000 M
Ω
40.00 M
Ω
0.1
Ω
0.001 k
Ω
0.01 k
Ω
0.1 k
Ω
0.001 M
Ω
0.01 M
Ω
0.9 % + 2
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
5 % + 2
Diode test
2.000 V
0.001 V
0.9 % + 2
Capacitance
1000 nF
10.00
μ
F
100.0
μ
F
9999
μ
F
1 nF
0.01
μ
F
0.1
μ
F
1
μ
F
1.9 % + 2
1.9 % + 2
1.9 % + 2
100
μ
F - 1000
μ
F: 1.9 % + 2
> 1000
μ
F: 5 % + 20
Lo-Z Capacitance
1 nF to 500
μ
F
10% + 2 typical
Temperature (Type K
Thermocouple)
-40 ºC to 400 ºC
-40 ºF to 752 ºF
0.1 ºC
0.2 ºF
1 % + 10
[2]
1 % + 18
[2]