Fluke 1577 Fluke 1577 and 1587 Insulation Multimeter Datasheet - Page 5
General Specifications - insulation meter
View all Fluke 1577 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Model 1587 Output Voltage 50 V (0 % to + 20 %) 100 V (0 % to + 20 %) 250 V (0 % to + 20 %) 500 V (0 % to + 20 %) 1000 V (0 % to + 20 %) Display Range 0.01 to 6.00 MΩ 6.0 to 50.0 MΩ 0.01 to 6.00 MΩ 6.0 to 60.0 MΩ 60 to 100 MΩ 0.1 to 60.0 MΩ 60 to 250 MΩ 0.1 to 60.0 MΩ 60 to 500 MΩ 0.1 to 60.0 MΩ 60 to 600 MΩ 0.6 to 2.0 GΩ Model 1577 Output Voltage 500 V (0 % to + 20 %) 1000 V (0 % to + 20 %) Display Range 0.1 to 60.0 MΩ 60 to 500 MΩ 0.1 to 60.0 MΩ 60 to 600 MΩ Resolution 0.01 MΩ 0.1 MΩ 0.01 MΩ 0.1 MΩ 1 MΩ 0.1 MΩ 1 MΩ 0.1 MΩ 1 MΩ 0.1 MΩ 1 MΩ 100 MΩ Resolution 0.1 MΩ 1 MΩ 0.1 MΩ 1 MΩ Test Current 1 mA @ 50 kΩ 1 mA @ 100 kΩ 1 mA @ 250 kΩ 1 mA @ 500 kΩ 1 mA @ 1 MΩ Resistance Accuracy 3 % + 5 counts 3 % + 5 counts 1.5 % + 5 counts 1.5 % + 5 counts 1.5 % + 5 counts 10 % + 3 counts Test Current 1 mA @ 500 kΩ 1 mA @ 1 MΩ Resistance Accuracy 2.0 % + 5 counts 2.0 % + 5 counts 1587/1577 General Specifications Maximum voltage applied to any terminal: 1000 V ac rms or dc Storage temperature: -40 °C to 60 °C (-40 °F to 140 °F) Operating temperature: -20 °C to 55 °C (-4 °F to 131 °F) Temperature coefficient: 0.05 x (specified accuracy) per °C for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F) Relative humidity, non-condensing: < °C 0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F) 0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F) 0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F) Vibration: Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument Shock: 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) Electromagnetic compatibility: In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: specified accuracy ± 5 °C (9 °F). (EN 61326-1:1997) Safety: Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V Certifications: CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard EN 61010 Part 1-1002 Batteries: Four AA batteries (NEDA 15A or IEC LR6) Battery life: Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off Size: 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L) Weight: 550 g (1.2 lb) IP rating: IP40 Altitude (operating): 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V Storage: 12,000 m Over-range capability: 110 % of range except for capacitance which is 1 % Compliance to EN 61557: IEC61557-1, IEC61557-2 1587/1577 Insulation Multimeters Fluke Corporation 5