Fluke 1623-2 Manual - Page 14

Features, Table 3. Features and Functions, Description - earth ground tester manual

Page 14 highlights

1623-2 Users Manual Features Typical applications for the Tester include: • Earth/ground resistance measurements in different installations, such as, high voltage pylons, buildings, electrical service grounding systems, mobile communication stations, and HF transmitters. • Monitor and plan lightning protection systems • Resistance measurements with earth electrodes; no separation See Table 3 for a list of features and functions. Table 3. Features and Functions 4 1623-2 EARTH/GROUND TESTER 3 5 2 6 7 1 8 Item 11 9 10 Description Rotary switch to select measurement function and ON/OFF "START" button to start the selected measurement function Liquid crystal display (LCD) Connection "H/C2" for auxiliary earth (4 mm ∅) Connection "S/P2" for probe (4 mm ∅) Connection  for sense current test clamp Connection "ES/P1" for earth electrode probe (4 mm ∅) Connection "E/C1" for the earth/ground electrode to be measured (4 mm ∅) Battery compartment for 6 alkaline batteries (type AA, LR6) Screws to fasten the battery compartment USB Type B Port edv001.eps 6 MyFlukeStore Shop for Fluke products online at: www. .com 1.877.766.5412

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

1623-2
Users Manual
6
Features
Typical applications for the Tester include:
Earth/ground resistance measurements in different installations, such as, high
voltage pylons, buildings, electrical service grounding systems, mobile
communication stations, and HF transmitters.
Monitor and plan lightning protection systems
Resistance measurements with earth electrodes; no separation
See Table 3 for a list of features and functions.
Table 3. Features and Functions
1623-2 EARTH/GROUND TESTER
2
3
4
5
6
7
8
11
9
10
1
edv001.eps
Item
Description
Rotary switch to select measurement function and ON/OFF
“START” button to start the selected measurement function
Liquid crystal display (LCD)
Connection “H/C2” for auxiliary earth (4 mm
)
Connection “S/P2” for probe (4 mm
)
Connection
for sense current test clamp
Connection “ES/P1” for earth electrode probe (4 mm
)
Connection “E/C1” for the earth/ground electrode to be measured (4 mm
)
Battery compartment for 6 alkaline batteries (type AA, LR6)
Screws to fasten the battery compartment
USB Type B Port
Shop for Fluke products online at:
1.877.766.5412
www.
MyFlukeStore