Page 14 highlights

1630 Users Manual Ground Leakage Current Measurement To perform a ground leakage current measurement test: 1. Open the jaws and make sure the surfaces fit together properly and are free of dust, dirt, or any foreign substances. 2. Turn the Clamp on by moving the rotary switch to the M or A function. 3. Attach the Clamp to the electrode or ground rod to be measured. Figure 4 shows a connection for a ground leakage current measurement. 4. Read the value of the leakage current on the display. 1630EARTH GROUND CLAMP HOLD OFF mA A CA3T00 V REC FUNC Figure 4. Ground Leakage Current Measurement eht05f.eps 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22

1630
Users Manual
8
Ground Leakage Current Measurement
To perform a ground leakage current measurement test:
1.
Open the jaws and make sure the surfaces fit together properly and
are free of dust, dirt, or any foreign substances.
2.
Turn the Clamp on by moving the rotary switch to the
M
or
A
function.
3.
Attach the Clamp to the electrode or ground rod to be measured.
Figure 4 shows a connection for a ground leakage current
measurement.
4.
Read the value of the leakage current on the display.
1630
EARTH GROUND CLAMP
300 V
CAT
mA
A
OFF
HOLD
FUNC
REC
eht05f.eps