Fluke 179 FE 175,177,179 Users Manual - Page 15

Specifications, ANSI/ISA S82.02.01, CSA C22.2-1010.1, IEC 61010 to 1000 V Overvoltage Category III

Page 15 highlights

Specifications Specifications Accuracy is specified for 1 yr after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 95 %. Accuracy specifications take the form of: ± ( [ % of Reading ] + [ Counts ] ) Maximum voltage between any terminal and earth ground: 1000 V DC or AC RMS Surge Protection: W Fuse for mA inputs: W Fuse for A input: 8 kV peak per IEC 61010 440 mA, 1000 V FAST Fuse 11 A, 1000 V FAST Fuse Display: Digital: 6000 counts, updates 4/sec Bar Graph: 33 segments; Updates 40/sec Frequency: 10,000 counts Capacitance: 1,000 counts Altitude: Operating: 2000 m; Storage: 12,000 m Temperature: Operating: −10 °C to +50 °C; Storage: −30 °C to +60 °C Temperature coefficient: 0.1 X (specified accuracy / °C (< 18 °C or > 28 °C) Electromagnetic Compatibility (EN 61326-1:1997): In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: specified accuracy ± 5 °C (9 °F) Relative Humidity: Noncondensing < 0 °C 0 % to 95 % @ 10 °C to 30 °C 0 % to 75 % @ 30 °C to 40 °C; 0 % to 40 % @ 40 °C to 50 °C Battery Life: Alkaline: 300 hrs typical Size (H x W x L): 4.3 cm x 9 cm x 18.5 cm Weight: 420 g Safety Compliances: Certifications: ANSI/ISA S82.02.01, CSA C22.2-1010.1, IEC 61010 to 1000 V Overvoltage Category III, 600 V Overvoltage P ; Category IV CSA, TÜV (EN61010), UL, , (N10140),VDE 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

Specifications
11
Specifications
Accuracy is specified for 1 yr after calibration, at operating temperatures of 18
°
C to 28
°
C, with relative humidity at 0 % to 95 %. Accuracy
specifications take the form of:
±
( [ % of Reading ] + [ Counts ] )
Maximum voltage between any terminal and earth ground:
1000 V DC or AC RMS
Surge Protection:
8 kV peak per IEC 61010
Fuse for mA inputs:
Fuse for A input:
440 mA, 1000 V FAST Fuse
11 A, 1000 V FAST Fuse
Display:
Digital: 6000 counts, updates 4/sec
Bar Graph:
33 segments;
Updates 40/sec
Frequency: 10,000 counts
Capacitance: 1,000 counts
Altitude:
Operating: 2000 m; Storage: 12,000 m
Temperature:
Operating:
-
10 °C to +50 °C;
Storage:
-
30 °C to +60 °C
Temperature coefficient:
0.1 X (specified accuracy / °C
(< 18 °C or > 28 °C)
Electromagnetic
Compatibility
(EN 61326-1:1997):
In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: specified accuracy
±
5 °C (9 °F)
Relative Humidity:
Noncondensing < 0 °C
0 % to 95 % @ 10 °C to 30 °C
0 % to 75 % @ 30 °C to 40 °C;
0 % to 40 % @ 40 °C to 50 °C
Battery Life:
Alkaline: 300 hrs typical
Size (H x W x L):
4.3 cm x 9 cm x 18.5 cm
Weight:
420 g
Safety Compliances:
ANSI/ISA S82.02.01, CSA C22.2-1010.1, IEC 61010 to 1000 V Overvoltage Category III, 600 V Overvoltage
Category IV
Certifications:
CSA, TÜV (EN61010), UL,
,
(
N10140),VDE