Fluke 179 FE 175,177,179 Users Manual - Page 7

Display, In MIN MAX AVG mode, MIN MAX - calibration

Page 7 highlights

Display . 5 6 4 3 2 1 7 8 7 9 13 12 11 14 10 15 No. 1 2 OSymbol s h3 K 4 Y 5 6 Amh MAX , MIN, AVG AIK02F.EPS Meaning Continuity test. Diode test. Negative readings. Unsafe voltage. Voltage ≥ 30 V, or voltage overload (OL) Display HOLD is enabled. Display freezes present reading. In MIN MAX AVG mode, MIN MAX AVG recording is interrupted. AutoHOLD is enabled. Display holds present reading until it detects new stable input. Then the Meter beeps and displays new reading. MIN MAX AVG enabled. Maximum, minimum, or average reading. Display No. Symbol Meaning 7 nµ F, °F, °C Measurement units. mVA, Mke, kHz 8 DC, AC 9 b Direct current, alternating current. Low battery. Replace battery. 10 610000mV All possible ranges. 11 Bar graph Analog display. 12 Auto Range The Meter selects the range with the best resolution. Manual Range The user selects the range. 13 ± Bar graph polarity. 14 0L 15 LEAd WThe input out of range. Test lead alert. Displayed when the rotary switch is moved to or from the mA or A position. bAtt diSC EEPr Err CAL Err Error Messages Replace the battery immediately. In the capacitance function, too much electrical charge is present on the capacitor being tested. Invalid EEPROM data. Have Meter serviced. Invalid calibration data. Calibrate Meter. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

Display
3
Display
8
7
7
5
6
4
3
2
1
13
14
15
9
11
12
10
AIK02F.EPS
No.
Symbol
Meaning
1
s
Continuity test.
2
Diode test.
3
K
Negative readings.
4
Y
Unsafe voltage. Voltage
30 V, or
voltage overload (
OL
)
5
Display HOLD is enabled. Display
freezes present reading.
In MIN MAX AVG mode, MIN MAX
AVG recording is interrupted.
AutoHOLD is enabled. Display holds
present reading until it detects new
stable input. Then the Meter beeps
and displays new reading.
6
MAX , MIN,
AVG
MIN MAX AVG enabled.
Maximum, minimum, or average
reading.
No.
Symbol
Meaning
7
n
μ
F,
°
F,
°
C
mVA, Mk
, kHz
Measurement units.
8
DC, AC
Direct current, alternating current.
9
b
Low battery. Replace battery.
10
610000mV
All possible ranges.
11
Bar graph
Analog display.
12
Auto Range
Manual Range
The Meter selects the range with
the best resolution.
The user selects the range.
13
±
Bar graph polarity.
14
0L
The input out of range.
15
LEAd
Test lead alert. Displayed when
the rotary switch is moved to or
from the
mA
or
A
position.
Error Messages
bAtt
Replace the battery immediately.
diSC
In the capacitance function, too much electrical
charge is present on the capacitor being tested.
EEPr
Err
Invalid EEPROM data. Have Meter serviced.
CAL
Err
Invalid calibration data. Calibrate Meter.