Fluke 289 Fluke 287 and 289 Multimeter Users Manual - Page 20

Understanding the Rotary Switch, S - low ohm

Page 20 highlights

287/289 Users Manual Understanding the Rotary Switch Select a primary measurement function by positioning the rotary switch to one of the icons around its perimeter. For each function, the Meter presents a standard display for that function (range, measurement units, and modifiers). Button choices made in one function do not carry over into another function. The model 289 offers two additional functions: low ohms (Y) and low impedance (LoZ) ac volts. Each position shown in Figure 3 is described in Table 4. Figure 3. Rotary Switch est03.emf 10 Table 4. Rotary Switch Positions Switch Position Function L AC voltage measurement using a low input impedance (model 289 only) V AC voltage measurements T AC millivolt measurements U DC and ac+dc voltage measurements N S P DC millivolts, ac+dc millivolt, and temperature measurements Resistance, continuity, and conductance measurements Diode test and capacitance measurements A AC, dc and ac+dc amps and milliamps measurements X Y AC, dc and ac+dc microampere measurements up to 5,000 μA Resistance measurements with 50e range (model 289 only)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

287/289
Users Manual
10
Understanding the Rotary Switch
Select a primary measurement function by positioning the rotary
switch to one of the icons around its perimeter. For each
function, the Meter presents a standard display for that function
(range, measurement units, and modifiers). Button choices made
in one function do not carry over into another function. The
model 289 offers two additional functions: low ohms (
Y
)
and
low impedance (
LoZ
) ac volts. Each position shown in Figure 3 is
described in Table 4.
est03.emf
Figure 3. Rotary Switch
Table 4. Rotary Switch Positions
Switch
Position
Function
L
AC voltage measurement using a low input
impedance (model 289 only)
V
AC voltage measurements
T
AC millivolt measurements
U
DC and ac+dc voltage measurements
N
DC millivolts, ac+dc millivolt, and
temperature measurements
S
Resistance, continuity, and conductance
measurements
P
Diode test and capacitance measurements
A
AC, dc and ac+dc amps and milliamps
measurements
X
AC, dc and ac+dc microampere
measurements up to 5,000
μ
A
Y
Resistance measurements with 50
e
range