Fluke 434/PWR Fluke 434/PWR Datasheet - Page 3
Technical Specifications - show
View all Fluke 434/PWR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
Technical Specifications Inputs Number of inputs Maximum input voltage Maximum sampling speed Volts/Amps/Hertz Vrms (AC+DC) Vpeak Voltage Crest Factor (CF) Arms (AC + DC) Apeak Crest factor, A Hz 50 Hz nominal Dips and swells Vrms (AC+DC) ² Arms (AC+DC) ² Harmonics Harmonic (interharmonic) Vrms Arms Watts DC voltage THD HZ Phase angle Power and energy Watt, VA, VAR kWh, kVAh, kVARh Power Factor/ Cos Ф / DPF Unbalance Volts Current Autotrend recording Sampling Memory Recording time Zoom Logging Sampling Readings Averaging Recording time Zoom Memory Screens & data General Specifications Operating Temperature Safety Size Weight Battery Life Shock Vibration Case Warranty 4 voltage and current (3 phases + neutral) 1000 Vrms (6 kV peak) 200 kS/s on each channel simultaneously Measurement range 1 ... 1000 V 1 ... 1400 V 1.0 ... > 2.8 0 ... 20 kA 1.4x rms value 1 ... 10 40 ... 70 Hz Accuracy 0.5% of Vnom 5% of Vnom ±5% ±0.5% ± 5 counts 5% ±5% ±0.01 Hz 0.0% ... 100% of Vnom 0 ... 20 kA ±0.2% of nominal voltage ±1% ± 5 counts DC, 1..50; (Off, 1..49) measured according to IEC 61000-4-7 0.0 ... 1000 V 0.0 ... 4000 mV x clamp scaling Depends on clamp scaling and voltage 0.0 ... 1000 V 0.0 ... 100.0% 0 ... 3500 Hz -360° ... +360° ±0.05% of nominal voltage ±5% ± 5 counts ±5% ± n x 2% or reading, ± 10 counts ±0.2% of nominal voltage ±2.5% V and A (± 5% Watt) ± 1 Hz ± n × 1.5º 1.0 ... 20.00 MVA¹ 00.00 ...200.0 GVAh¹ 0...1 ±1% ± counts ±1.5% ± 10 counts ±0.03 0.0 ... 5.0% 0.0 ... 20% ±0.5% ± 1% 5 readings/sec continuous sampling per channel 1800 min, max and avg points for each reading Up to 450 days Up to 12x horizontal zoom 5 readings/sec continuous sampling per channel User selectable up to 100 readings on 3 phases and neutral simultaneously 2 hr down to 0.5s user selectable User selectable up to 7 MB of shared memory Yes 50, shared memory divided between logging, screens and data sets 0 ºC to +50 ºC EN61010-1 (2nd edition) pollution degree 2; 1000 V CAT III / 600 V CAT IV ANSI/ISA S82.01 256 x 169 x 64 mm 2 kg Rechargeable NiMH pack (installed): > 7 hours Battery charging time: 4 hours typical 30 g 3 g according to MIL-PRF-28800F Class 2 Rugged, shock proof with integrated protective holster, IP51 (drip and dust proof) 3 years 1) Depending on clamp scaling 2) Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle