Fluke TiR105 User Manual - Page 52

General Specifications, Caution

Page 52 highlights

Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125 Users Manual To get the best performance from the lithium-ion battery, use the guidelines that follow: • Do not store the Imager on the charger for more than 24 hours as reduced battery life may result. • Charge the Imager for a two-hour minimum at six-month intervals for maximum battery life. Without use, the battery will self-discharge in approximately six months. Batteries stored for long periods will need two to ten charging cycles for full capacity. • Always operate in the specified temperature range.   Caution Do not incinerate the Product and/or battery. Go to Fluke's website for recycling information. General Specifications Temperature Operating 10 °C to 50 °C (14 °F to 122 °F) Storage 20 °C to 50 °C (-4 °F to 122 °F) without batteries Charging 0 °C to 40 °C (32 °F to 104 °F) Relative Humidity 10 to 95 % non-condensing Altitude Operating 2,000 m Storage 12,000 m Safety Standards CE Directive IEC/EN 61010-1 2nd Edition Pollution Degree 2 Display Color LCD, 3.5″ diagonal (Portrait orientation) with Backlight (selectable high, medium, low) Controls and Adjustments User-selectable Temperature Scale (°C/°F) Center Point Temperature Language Selection Time and Date Settings Emissivity Selection Background (reflected) Compensation Transmission Correction (all models except Ti100, Ti105, TiR105) IR-Fusion® (all models except Ti100) Color Palettes Level and Span User-selectable Display Graphics 46

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125
Users Manual
46
To get the best performance from the lithium-ion battery, use the guidelines
that follow:
Do not store the Imager on the charger for more than 24 hours as reduced
battery life may result.
Charge the Imager for a two-hour minimum at six-month intervals for
maximum battery life. Without use, the battery will self-discharge in
approximately six months. Batteries stored for long periods will need two
to ten charging cycles for full capacity.
Always operate in the specified temperature range.
Caution
Do not incinerate the Product and/or battery. Go to Fluke’s
website for recycling information.
General Specifications
Temperature
Operating
............................................................
-10
°
C to 50
°
C (14
°
F to 122
°
F)
Storage
................................................................
-20
°
C to 50
°
C (-4
°
F to 122
°
F)
without batteries
Charging
..............................................................
0
°
C to 40
°
C (32
°
F to 104
°
F)
Relative Humidity
..................................................
10 to 95 % non-condensing
Altitude
Operating
.............................................................
2,000 m
Storage
................................................................
12,000 m
Safety Standards
CE Directive
........................................................
IEC/EN 61010-1 2nd Edition Pollution
Degree 2
Display
....................................................................
Color LCD, 3.5
diagonal (Portrait
orientation) with Backlight (selectable
high, medium, low)
Controls and Adjustments
User-selectable Temperature Scale (
°
C/
°
F)
Center Point Temperature
Language Selection
Time and Date Settings
Emissivity Selection
Background (reflected) Compensation
Transmission Correction (all models except Ti100, Ti105, TiR105)
IR-Fusion
®
(all models except Ti100)
Color Palettes
Level and Span
User-selectable Display Graphics