The stripe value should be selected based on different applications. It ranges

Page 86 highlights

4. The stripe value should be selected based on different applications. It ranges from 4KB to 128KB. Some suggested choices are : 16K - Best for sequential transfer. 64K - Good general purpose strip size. 128K - Best performance for most desktops and workstations. Keep it at Optimal default value. Press [F7] to finish the setting. MediaShield BIOS Jul 27 2007 - Define a New Array - RAID Mode: SMtirrirpoerdedM irror Stripe Block: Optimal Free Disks Port Disk Model Capacity Array Disks Port Disk Model Capacity All data on new (or added) disks will 0b.e0ovWerDwCrittWenD.1C2o0n0tJinDu-e9?111.79GB 0.1 HDS728080PLA38 76.79GB [+] Add 0.2 Hitachi HDT725 232.88GB [Y] YES [N] N0O.3 ST3320620AS 298.09GB [-] Del [ESC] Quit [F6] Back [F7] Finish [TAB] Navigate [↑↓] Select [ENTER] Popup 5. Press [Y] to continue, and press [Y] again to select "Clear MBR". 5 MediaShield BIOS Jul 27 2007 - Define a New Array - RAID Mode: SMtirrirpoerdedM irror Stripe Block: OOppttiimmaall Free Disks Port Disk Model Capacity Array Disks Port Disk Model Capacity Clear MBR? 0.0 0.1 [+] Add 0.2 [Y] YES [N] NO0.3 WDC WD1200JD-9 111.79GB HDS728080PLA38 76.69GB Hitachi HDT725 232.88GB ST3320620AS 298.09GB [-] Del [ESC] Quit [F6] Back [F7] Finish [TAB] Navigate [↑↓] Select [ENTER] Popup 79

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106

5
79
MediaShield BIOS
Jul 27 2007
- Define a New Array -
RAID Mode: Mirrored
Stripe Block:
Free Disks
Array Disks
Port
Disk Model
Port Disk Model
Capacity
[-] Del
[ESC] Quit
[F6] Back
[F7] Finish
[TAB] Navigate
[↑↓] Select
[ENTER] Popup
4. The stripe value should be selected based on different applications. It ranges from
4KB to 128KB. Some suggested choices are :
16K - Best for sequential transfer.
64K - Good general purpose strip size.
128K - Best performance for most desktops and workstations.
Keep it at Optimal default value. Press [F7] to finish the setting.
5. Press [Y] to continue, and press [Y] again to select "Clear MBR".
MediaShield BIOS
Jul 27 2007
- Define a New Array -
RAID Mode: Mirrored
Stripe Block:
Free Disks
Array Disks
Port
Capacity
[-] Del
[ESC] Quit
[F6] Back
[F7] Finish
[TAB] Navigate
[↑↓] Select
[ENTER] Popup
Striped Mirror
Optimal
All data on new (or added) disks will be overwritten. Continue?
[Y] YES
[N] NO
Striped Mirror
Optimal
0.1 HDS728080PLA38 76.69GB
Hitachi HDT725
232.88GB
0.3 ST3320620AS
298.09GB
0.0 WDC WD1200JD-9 111.79GB
Clear MBR?
[Y] YES