Frigidaire AGQ7000EE Data Sheet - Page 3

Check, Correction

Page 3 highlights

Test Test 1: Test 2: Test 3: Test 4: Test 5: Test 6: Test 7: Check 1. Is the incoming water flow normal? Test 2. Are the incoming water faucets turned 3. Is the incoming water pressure above (30) psi. 4. Does the fill water continue to enter the washer? 5. Remove power from the washer. Did the water fill stop? 6. Check the pressure sensor. 7. Replace the control board. 1. Is the washer leaking water? 2. Is there an air leak in the air bell system? 3. Check the pressure sensor. 4. Replace the control board. 1. Check the drain hose for restrictions. 2. Start the washer and check for 120 VAC at the drain pump. Inspect the wiring between the pressure sensor and the control board. 1. Is the water level above 4.5 inches? 2. Does water enter the washer continuously. 3. Remove power from washer. Does the water stop coming in? 4. Replace the pressure sensor switch. Did this correct the problem? 1. Is the loading door closed? 2. In the J2 plug on the console control, measure voltage from the black wire to ground with power on. Correction Yes. Go to step (4). No. Go to step (2) No. Turn water faucets on. Yes. Go to step (3). No. Have customer correct pressure problem. Yes. Check for kinked or blocked incoming water hoses, clean the incoming water screens. If problem still remains, replace the water inlet valve assembly. Yes. Go to step (5). No. Go to step (6) Yes. Go to step (6) No. Replace the inlet valve assembly. Pressure sensor checks good. Go to step (7). Pressure sensor checks bad. Replace pressure sensor. Yes. Correct water leak. No. Go to step (2) Yes. Correct the air leak problem. No. Go to step (3) Defective. Replace the pressure sensor. Good. Go to step (4) Restriction. Correct problem. No restriction. Go to step (2). Zero. Replace the control board. 120 VAC. Remove the pump and check for blockage. If blocked, remove the restriction, if not, replace the pump. Defective wiring. Correct wiring. Good wiring. Replace the pressure sensor. If this does not correct the problem, replace the control board. Yes. Go to step (2). No. Go to step (4). Yes. Go to step (3). No. Replace the control board. No. Replace water valve assembly. Yes. Check wiring to valve assembly for shorts. If wiring is good, replace the control board. Yes. Problem solved. No. Replace the control board. No. Close the door. Yes. Go the step (2). 0 volts. Check the door strike. If good, replace the door switch assembly. 120 volts. Replace the console control board. 1. Start the diagnostic test. Turn the program knob 8 clicks clockwise from the start position. Washer spins. Defective door lock assembly. Washer does not spin. Defective control board. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

3
Test
Test
Check
Correction
Test 1:
Test 2:
Test 3:
Test 4:
Test 5:
Test 6:
Test 7:
Yes. Go to step (4).
No. Go to step (2)
No. Turn water faucets on.
Yes. Go to step (3).
No. Have customer correct pressure problem.
Yes. Check for kinked or blocked incoming water
hoses, clean the incoming water screens. If
problem still remains, replace the water inlet valve
assembly.
Yes. Go to step (5).
No. Go to step (6)
Yes. Go to step (6)
No. Replace the inlet valve assembly.
Pressure sensor checks good.
Go to step (7).
Pressure sensor checks bad. Replace pressure
sensor.
Yes. Correct water leak.
No. Go to step (2)
Yes. Correct the air leak problem.
No. Go to step (3)
Defective. Replace the pressure sensor.
Good. Go to step (4)
Restriction. Correct problem.
No restriction. Go to step (2).
Zero. Replace the control board.
120 VAC. Remove the pump and check for blockage.
If blocked, remove the restriction, if not, replace
the pump.
Defective wiring. Correct wiring.
Good wiring. Replace the pressure sensor. If this
does not correct the problem, replace the control
board.
Yes. Go to step (2).
No. Go to step (4).
Yes. Go to step (3).
No. Replace the control board.
No. Replace water valve assembly.
Yes. Check wiring to valve assembly for shorts. If
wiring is good, replace the control board.
Yes. Problem solved.
No. Replace the control board.
No. Close the door.
Yes. Go the step (2).
0 volts. Check the door strike. If good, replace the
door switch assembly.
120 volts. Replace the console control board.
Washer spins. Defective door lock assembly.
Washer does not spin. Defective control board.
1. Is the incoming water flow normal?
2.
Are the incoming water faucets turned
3.
Is the incoming water pressure above (30) psi.
4.
Does the fill water continue to enter the washer?
5.
Remove power from the washer. Did the water fill stop?
6. Check the pressure sensor.
7. Replace the control board.
1. Is the washer leaking water?
2. Is there an air leak in the air bell system?
3. Check the pressure sensor.
4. Replace the control board.
1. Check the drain hose for restrictions.
2. Start the washer and check for 120 VAC at the drain
pump.
Inspect the wiring between the pressure sensor and the
control board.
1.
Is the water level above 4.5 inches?
2.
Does water enter the washer continuously.
3.
Remove power from washer. Does the water stop coming
in?
4.
Replace the pressure sensor switch. Did this correct the
problem?
1.
Is the loading door closed?
2.
In the J2 plug on the console control, measure voltage
from the black wire to ground with power on.
1.
Start the diagnostic test. Turn the program knob 8
clicks clockwise from the start position.