Frigidaire FARE4044MW Installation Instructions (English, Español, Fr - Page 10

Important, Warning

Page 10 highlights

INSTALLATION REQUIREMENTS Clearance requirements IMPORTANT DO NOT INSTALL YOUR DRYER: 1 In an area exposed to dripping water or outside weather conditions. 2 In an area where it will come in contact with curtains, drapes, or anything that will obstruct the flow of combustion and ventilation air. 3 On carpet. Floor MUST be solid with a maximum slope of 1 inch (2.54 cm). MINIMUM INSTALLATION CLEARANCES - Inches (cm) SIDES REAR TOP FRONT Alcove 0" (0 cm) 0" (0 cm)* 23" (58.5 cm) n/a Closet 0" (0 cm) 0" (0 cm)* 23" (58.5 cm) 1" (2.5 cm) * Dryer must be vented straight back to achieve 0" (0 cm) rear installation. 0" (0 cm) 0" (0 cm) 1" (2.5 cm) 0" (0 cm) WARNING EXPLOSION HAZARD Do not install the dryer where gasoline or other flammables are kept or stored. If the dryer is installed in a garage, it must be a minimum of 18 inches (45.7 cm) above the floor. Failure to do so can result in death, explosion, fire or burns. 23" (58.5 cm) Dryer Dimensions 27" (68.5 cm) 50" (127 cm) to clear open door 37" (94 cm) 43" (109 cm) 1.6" (4 cm) electrical supply on rear of unit1 gas supply pipe on rear of gas unit 3.75" (9.5 cm) 13.50" (34.5 cm) to center of rear vent 1Power supply cord length on gas unit approximately 60 inches (152.5 cm). 10 centerline height for rear vent 3.7" (9.5 cm) floor line 29" (73.5 cm) to front of closed door

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

10
13.50”
(34.5 cm)
to center of rear vent
INSTALLATION REQUIREMENTS
* Dryer must be vented straight back to achieve
0” (0 cm) rear installation.
centerline height
for rear vent
MINIMUM INSTALLATION CLEARANCES - Inches (cm)
SIDES
REAR
TOP
FRONT
Alcove
0” (0 cm)
0” (0 cm)*
23” (58.5 cm)
n/a
Closet
0” (0 cm)
0” (0 cm)*
23” (58.5 cm)
1” (2.5 cm)
1”
(2.5 cm)
0”
(0 cm)
23”
(58.5 cm)
Clearance requirements
IMPORTANT
DO NOT INSTALL YOUR DRYER:
1
In an area exposed to dripping water or outside
weather conditions.
2
In an area where it will come in contact with
curtains, drapes, or anything that will obstruct
the
ow of combustion and ventilation air.
3
On carpet. Floor MUST be solid with a maximum
slope of 1 inch (2.54 cm).
0”
(0 cm)
0”
(0 cm)
27” (68.5 cm)
29” (73.5 cm)
to front of closed door
50” (127 cm)
to clear open door
oor line
1.6”
(4 cm)
3.75”
(9.5 cm)
3.7”
(9.5 cm)
43”
(109 cm)
37”
(94 cm)
gas supply
pipe on rear
of gas unit
electrical
supply on
rear of unit
1
Dryer Dimensions
1
Power supply cord length on gas unit approximately 60 inches (152.5 cm).
WARNING
EXPLOSION HAZARD
Do not install the dryer where gasoline or other
ammables are kept or stored. If the dryer is installed
in a garage, it must be a minimum of 18 inches (45.7
cm) above the
oor. Failure to do so can result in
death, explosion,
re or burns.