Frigidaire FASE7073LR Installation Instructions (All Languages) - Page 10
Clearance requirements, continued
UPC - 012505382444
View all Frigidaire FASE7073LR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
INSTALLATION REQUIREMENTS Clearance requirements, continued Installation in a Recess or Closet 1 A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors. 2 No other fuel burning appliance shall be installed in the same closet as the gas dryer. 3 Your dryer needs the space around it for proper ventilation. DO NOT install your dryer in a closet with a solid door. 4 Closet door ventilation required: A minimum of 120 square inches (774.2 cm²) of opening, equally divided at the top and bottom of the door, is required. Openings should be located 3 inches (7.6 cm) from bottom and top of door. Openings are required to be unobstructed when a door is installed. A louvered door with equivalent air openings for the full length of the door is acceptable. MINIMUM INSTALLATION CLEARANCES - Inches (cm) SIDES REAR TOP FRONT Alcove 0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a UnderCounter 0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a Closet 0" (0 cm) 0" (0 cm)* 0" (0 cm) 1" (2.54 cm) * Dryer must be vented straight back to achieve 0" (0 cm) rear installation. 0" (0cm) 0" (0cm) 3" (7.6cm) 60 sq. in. (387.1cm²) 1" (2.54cm) 0" (0cm) 3" (7.6cm) closet door 60 sq. in. (387.1cm²) 10