CONNECTING THE WATER SUPPLY WARNING To avoid electric shock, which can cause death or severe personal injury, disconnect the refrigerator from electrical power before connecting a water supply line to the refrigerator. CAUTION To Avoid Property Damage: • Copper or Stainless Steel braided tubing is recommended for the water supply line. Water supply tubing made of ¼ inch plastic is not recommended to be used. Plastic tubing greatly increases the potential for water leaks, and the manufacturer will not be responsible for any damage if plastic tubing is used for the supply line. • DO NOT install water supply tubing in areas where temperatures fall below freezing. • Chemicals from a malfunctioning water softener can damage the ice maker. If your home has a water softening system, ensure the softener is maintained and working properly.  NOTE Check with your local building authority for recommendations on water lines and associated materials prior to installing your new refrigerator. Depending on your local/state building codes, Frigidaire recommends for homes with existing valves its Smart Choice® water line kit 5305513409 (with a 6 ft. Stainless Steel Water Line) and for homes without an existing valve, Frigidaire recommends its Smart Choice® water line kit 5305510264 (with a 20 ft. Copper Water Line with self-tapping saddle valve). Please refer to www.frigidaire.com/store for more information. IMPORTANT Ensure that your water supply line connections comply with all local plumbing codes. Before Installing The Water Supply Line, You Will Need: • Basic Tools: adjustable wrench, flat-blade screwdriver, and PhillipsTM screwdriver • Access to a household cold water line with water pressure between 30 and 100 psi. • A water supply line made of ¼ inch (6.4 mm) OD, copper or stainless steel tubing. To determine the length of tubing needed, measure the distance from the ice maker inlet valve at the back of the refrigerator to your cold water pipe. Then add approximately 7 feet (2.1 meters), so the refrigerator can be moved out for cleaning (as shown). • A shutoff valve to connect the water supply line to your household water system. DO NOT use a selfpiercing type shutoff valve. • Do not re-use compression fitting or use thread seal tape. • A compression nut and ferrule (sleeve) for connecting a copper water supply line to the ice maker inlet valve. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33

13
CONNECTING THE WATER SUPPLY
WARNING
To avoid electric shock, which can cause
death or severe personal injury, disconnect
the refrigerator from electrical power before
connecting a water supply line to the refrigerator.
NOTE
Check with your local building authority for
recommendations on water lines and associated
materials prior to installing your new refrigerator.
Depending on your local/state building codes, Frigidaire
recommends for homes with existing valves its Smart
Choice
®
water line kit 5305513409 (with a 6 ft. Stainless
Steel Water Line) and for homes without an existing
valve, Frigidaire recommends its Smart Choice
®
water
line kit 5305510264 (with a 20 ft. Copper Water Line
with self-tapping saddle valve). Please refer to
www.frigidaire.com/store for more information.
CAUTION
To Avoid Property Damage:
• Copper or Stainless Steel braided tubing is
recommended for the water supply line. Water
supply tubing made of ¼ inch plastic is not
recommended to be used. Plastic tubing greatly
increases the potential for water leaks, and the
manufacturer will not be responsible for any
damage if plastic tubing is used for the supply
line.
• DO NOT install water supply tubing in areas
where temperatures fall below freezing.
• Chemicals from a malfunctioning water
softener can damage the ice maker. If your
home has a water softening system, ensure the
softener is maintained and working properly.
IMPORTANT
Ensure that your water supply line connections comply
with all local plumbing codes.
Before Installing The Water Supply Line, You Will
Need:
Basic Tools: adjustable wrench, flat-blade screwdriver,
and Phillips
TM
screwdriver
Access to a household cold water line with water
pressure between 30 and 100 psi.
A water supply line made of ¼ inch (6.4 mm) OD,
copper or stainless steel tubing. To determine the
length of tubing needed, measure the distance from
the ice maker inlet valve at the back of the refrigerator
to your cold water pipe. Then add approximately
7 feet (2.1 meters), so the refrigerator can be moved
out for cleaning (as shown).
A shutoff valve to connect the water supply line to
your household water system. DO NOT use a self-
piercing type shutoff valve.
Do not re-use compression fitting or use thread seal
tape.
A compression nut and ferrule (sleeve) for connecting
a copper water supply line to the ice maker inlet valve.