Frigidaire FFHP093CS2 Installation Instructions - Page 18
Connect the cable to the indoor unit
View all Frigidaire FFHP093CS2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
Connect the cable to the indoor unit 1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible type cord. 3. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw. 4. Ensure the wire color of the outdoor terminal and indoor terminal correspond respectively. 5. Wrap the cable not connected to the terminal block with insulation tape so that they will not come in contact with any electrical components. Secure the cable onto the control board with the cord clamp. Electrical box cover Cable Code wire Terminal block of indoor unit N(1) 2 3 0.39" 1.57" To Outdoor Unit 17 Electrical work