Frigidaire FFLE2022MW Installation Instructions - Page 15

Warning, Important

Page 15 highlights

INSTALLATION INSTRUCTIONS Electrical connection (non-Canada) - 3 wire cord 3-wire receptacle (NEMA type 10-30R) WARNING ELECTRICAL SHOCK HAZARD Failure to disconnect power source before servicing could result in personal injury or even death. 1 Turn off power supply to outlet. 2 Remove the screw securing the terminal block access cover on the back of the dryer. 3 Install a UL-approved strain relief according to the power cord/strain relief manufacturer's instructions in the power cord entry hole below the access panel. At this time, the strain relief should be loosely in place. 4 Thread an UNPLUGGED, UL-approved, 30 amp. power cord, NEMA 10-30 type SRDT, through the strain relief. 5 Attach the power cord neutral (center wire) conductor to the SILVER colored center terminal on the terminal block. Tighten the screw securely. 6 Attach the remaining two power cord outer conductors to the outer, BRASS colored terminals on the terminal block. Tighten both screws securely. WARNING ELECTRICAL SHOCK HAZARD Do not make a sharp bend or crimp wiring/conductor at connections. 7 Follow manufacturer's guidelines for firmly securing the strain relief and power cord. 8 Reinstall the terminal block cover. IMPORTANT If moving dryer from a 4-wire system and installing it in a 3-wire system, move the internal ground from the center terminal back to the GREEN screw next to the terminal block. 30 AMP NEMA 10-30 DO NOT remove internal ground in a 3-wire system! Neutral (center wire) Neutral terminal 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

15
1
Turn off power supply to outlet.
2
Remove the screw securing the terminal block
access cover on the back of the dryer.
3
Install a UL-approved strain relief according to the
power cord/strain relief manufacturer’s instructions
in the power cord entry hole below the access
panel. At this time, the strain relief should be
loosely in place.
4
Thread an UNPLUGGED, UL-approved, 30 amp.
power cord, NEMA 10-30 type SRDT, through the
strain relief.
5
Attach the power cord neutral (center wire)
conductor to the SILVER colored center terminal on
the terminal block. Tighten the screw securely.
6
Attach the remaining two power cord outer
conductors to the outer, BRASS colored terminals on
the terminal block. Tighten both screws securely.
7
Follow manufacturer’s guidelines for
rmly securing
the strain relief and power cord.
8
Reinstall the terminal block cover.
Neutral
terminal
DO NOT remove
internal ground in a
3-wire system!
Electrical connection (non-Canada) - 3 wire cord
3-wire receptacle
(NEMA type 10-30R)
Neutral
Neutral
(center wire)
(center wire)
30 AMP
30 AMP
NEMA 10-30
NEMA 10-30
WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source before servicing
could result in personal injury or even death.
WARNING
ELECTRICAL SHOCK HAZARD
Do not make a sharp bend or crimp wiring/conductor
at connections.
IMPORTANT
If moving dryer from a 4-wire system and installing it
in a 3-wire system, move the internal ground from the
center terminal back to the GREEN screw next to the
terminal block.