Frigidaire FFSS2615TS Complete Owner s Guide - Page 27

Before You Call

Page 27 highlights

BEFORE YOU CALL 1-800-944-9044 (United States) 1-800-265-8352 (Canada) Visit our web site at www.frigidaire.com CONCERN CAUSE AUTOMATIC ICE MAKER Ice maker is not making any ice. • Ice maker wire signal arm is in the "up" or OFF position. • Ice maker has small cube caught in mechanism. Ice maker is not making enough ice. • Saddle valve on cold water pipe is clogged or restricted by foreign material. • Ice maker is producing less ice than you expect. • Check to see if water dispenser is dispensing slower than normal. • Freezer control is set too warm. Ice maker will • Ice maker wire signal arm not stop making ice. is being held down by some item in the freezer. Ice cubes are • Ice cubes are not being freezing together. used frequently enough. • Ice cubes are hollow (partially frozen cubes with water inside). • Freezer control is set too warm. DISPENSER (Ice & Water) Dispenser will not dispense ice. • Dispenser lock out is engaged. • There is no ice in the bin to be dispensed. • The refrigerator doors are not completely closed. • Dispenser paddle has been pressed too long and the dispenser motor has overheated. Ice dispenser is jammed. • Ice has melted and frozen around auger due to infrequent use, temperature fluctuations, and/or power outages. • Ice cubes are jammed between ice maker and back of ice container. SOLUTION • Move wire signal arm to the "down" or ON position (side mounted). • Remove small cube from ice maker. The ice and water filter cartridge may be clogged. Replace filter cartridge. • Turn off household water line valve. Remove valve. Ensure that valve is not a self-piercing saddle valve. Clean valve. Replace valve if necessary. • Side mounted ice maker should produce 4 to 4.5 pounds (approximately 4 quarts) of ice every 24 hours. • If it is, replace the ice and water filter cartridge. • Set freezer control to colder setting to improve performance of the ice maker. Allow 24 hours for temperature to stabilize. • Move item and release wire signal arm. Remove any ice cubes that are frozen together over the wire signal arm. • Remove ice container and discard ice from container. Ice maker will produce fresh supply. • The ice and water filter cartridge may be clogged. Replace filter cartridge. • Set freezer control to colder setting. Allow 24 hours for temperature to stabilize. • Press and hold control lock for three seconds. • See the "Ice maker is not making any ice" section above. • Be sure the refrigerator doors are completely closed. • The motor overload protector will reset in about three minutes and then ice can be dispensed. • Remove ice container, thaw, and empty the contents. Clean container, wipe dry, and replace in proper position. When new ice is made, dispenser should operate. • Remove ice cubes that are jamming the dispenser. 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

27
BEFORE YOU CALL
Visit our web site at
www.frigidaire.com
1-800-944-9044
(United States)
1-800-265-8352
(Canada)
CONCERN
CAUSE
SOLUTION
AUTOMATIC ICE MAKER
Ice maker is
not making any
ice.
• Ice maker wire signal arm is
in the “up” or OFF position.
• Ice maker has small cube
caught in mechanism.
• Saddle valve on cold
water pipe is clogged
or restricted by foreign
material.
• Move wire signal arm to the “down” or ON
position (side mounted).
• Remove small cube from ice maker. The
ice and water filter cartridge may be
clogged. Replace filter cartridge.
• Turn off household water line valve.
Remove valve. Ensure that valve is not
a self-piercing saddle valve. Clean valve.
Replace valve if necessary.
Ice maker is
not making
enough ice.
• Ice maker is producing
less ice than you expect.
• Check to see if water
dispenser is dispensing
slower than normal.
• Freezer control is set too
warm.
• Side mounted ice maker should produce 4
to 4.5 pounds (approximately 4 quarts) of
ice every 24 hours.
If it is, replace the ice and water filter
cartridge.
• Set freezer control to colder setting to im-
prove performance of the ice maker. Allow
24 hours for temperature to stabilize.
Ice maker will
not stop mak-
ing ice.
• Ice maker wire signal arm
is being held down by
some item in the freezer.
• Move item and release wire signal arm.
Remove any ice cubes that are frozen
together over the wire signal arm.
Ice cubes are
freezing to-
gether.
• Ice cubes are not being
used frequently enough.
• Ice cubes are hollow
(partially frozen cubes
with water inside).
• Freezer control is set too
warm.
• Remove ice container and discard ice from
container. Ice maker will produce fresh supply.
The ice and water filter cartridge may be
clogged. Replace filter cartridge.
• Set freezer control to colder setting. Allow
24 hours for temperature to stabilize.
DISPENSER (Ice & Water)
Dispenser will
not dispense
ice.
• Dispenser lock out is
engaged.
• There is no ice in the bin
to be dispensed.
• The refrigerator doors are
not completely closed.
• Dispenser paddle has
been pressed too long
and the dispenser motor
has overheated.
• Press and hold control lock for three
seconds.
• See the “Ice maker is not making any ice”
section above.
• Be sure the refrigerator doors are com-
pletely closed.
• The motor overload protector will reset in
about three minutes and then ice can be
dispensed.
Ice dispenser is
jammed.
• Ice has melted and
frozen around auger
due to infrequent use,
temperature fluctuations,
and/or power outages.
• Ice cubes are jammed
between ice maker and
back of ice container.
• Remove ice container, thaw, and empty
the contents. Clean container, wipe dry,
and replace in proper position. When new
ice is made, dispenser should operate.
• Remove ice cubes that are jamming the
dispenser.