Frigidaire FGGF304DLW Installation Instructions (All Languages) - Page 6

Electrical Requirements, Burner Grates, Electric Ignition Surface Burners

Page 6 highlights

30" GAS RANGE INSTALLATION INSTRUCTIONS 5 Electrical Requirements 120 volt, 60 Hertz, properly grounded dedicated circuit protected by a 15 amp circuit breaker or time delay fuse. Note: Not recommended to be installed with a Ground Fault Interrupt (GFI). Do not use an extension cord with this range. Grounding Instructions IMPORTANT Please read carefully. For personal safety, this appliance must be properly grounded. The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong grounding wall receptacle (see Figure 6) to minimize the possibility of electric shock hazard from the appliance. The wall receptacle and circuit should be checked by a qualified electrician to make sure the receptacle is properly grounded. Preferred Method Grounding type wall receptacle Do not, under any circumstances, cut, remove, or bypass the grounding prong. Power supply cord with 3-prong grounding plug. Figure 6 Where a standard 2-prong wall receptacle is installed, it is the personal responsibility and obligation of the consumer to have it replaced by a properly grounded 3-prong wall receptacle. Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. Disconnect electrical supply cord from wall receptacle before servicing cooktop. 6 Assembly of the Burner Caps and Burner Grates It is very important to make sure that all of the surface burner caps and surface burner grates are installed correctly and in the correct locations. Burner Cap Fixed Burner Head Gas Opening Please note: The burner heads are secured to the cooktop. THE COOKTOP IS NOT REMOVABLE. Do not attempt to remove or lift the cooktop. REMEMBER - DO NOT ALLOW SPILLS' FOOD' CLEANING AGENTS OR ANY OTHER MATERIAL TO ENTER THE GAS OPENING OF THE BURNER. Always keep the Burner Caps in place whenever the surface burners are in use. 7 Electric Ignition Surface Burners Operation of electric igniters should be checked after range and supply line connectors have been carefully checked for leaks, and range has been connected to electric power. To check for proper lighting: A. Push in and turn a surface burner knob to the LITE position. You will hear the igniter sparking. B. The surface burner should light when gas is available to the top burner. Each burner should light within four (4) seconds after air has been purged from supply lines. Visually check that burner has lit. C. Once the burner lights, the control knob should be rotated out of the LITE position. D. There are separate ignition devices for each burner. Try each knob separately until all burner valves have been checked. 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

6
30" GAS RANGE INSTALLATION INSTRUCTIONS
5
Electrical Requirements
120 volt, 60 Hertz, properly grounded dedicated circuit
protected by a 15 amp circuit breaker or time delay
fuse.
Note:
Not recommended to be installed with a Ground
Fault Interrupt (GFI).
Do not use an extension cord with this range.
Grounding Instructions
IMPORTANT Please read carefully.
For personal safety, this appliance must be
properly grounded.
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong grounding wall receptacle (see Figure 6) to
minimize the possibility of electric shock hazard from the
appliance.
The wall receptacle and circuit should be checked by
a qualified electrician to make sure the receptacle is
properly grounded.
6
Assembly of the Burner Caps and
Burner Grates
It is very important to make sure that all of the surface
burner caps and surface burner grates are installed
correctly and in the correct locations.
Burner
Cap
Fixed
Burner
Head
Gas
Opening
7
Electric Ignition Surface Burners
Operation of electric igniters should be checked after
range and supply line connectors have been carefully
checked for leaks, and range has been connected to
electric power. To check for proper lighting:
A.
Push in and turn a surface burner knob to the LITE
position. You will hear the igniter sparking.
B.
The surface burner should light when gas is
available to the top burner. Each burner should light
within four (4) seconds after air has been purged
from supply lines. Visually check that burner has lit.
C.
Once the burner lights, the control knob should be
rotated out of the LITE position.
D.
There are separate ignition devices for each burner.
Try each knob separately until all burner valves have
been checked.
Please note: The
burner heads
are secured to
the cooktop. THE
COOKTOP IS NOT
REMOVABLE.
Do not
attempt to remove or lift
the cooktop.
REMEMBER -
DO NOT
ALLOW SPILLS' FOOD'
CLEANING AGENTS OR
ANY OTHER MATERIAL
TO ENTER THE GAS
OPENING OF THE
BURNER.
Always keep
the Burner Caps in place
whenever the surface
burners are in use.
Preferred Method
Grounding type
wall receptacle
Do not, under any
circumstances,
cut, remove,
or bypass the
grounding prong.
Power supply
cord with 3-prong
grounding plug.
Figure 6
Where a standard 2-prong wall receptacle is installed,
it is the personal responsibility and obligation of the
consumer to have it replaced by a properly grounded
3-prong wall receptacle.
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
Disconnect electrical supply cord from
wall receptacle before servicing cooktop.