SERVICE CALL CHECK Please check the following before calling for service: Place one cup of water in a glass measuring cup in the microwave oven and close the door securely. Operate the microwave oven for one minute at HIGH 100%. A Does the microwave oven light come on? YES ____ NO ____ B Does the cooling fan work? (Put your hand on the louver above the Control Panel.) YES ____ NO ____ C Does the turntable rotate? (It is normal for the turntable to turn in either direction.) YES ____ NO ____ D Is the water in the microwave oven warm? YES ____ NO ____ If "NO" is the answer to any of the above questions, please check electrical outlet, fuse and/or circuit breaker. If they are functioning properly, CONTACT YOUR NEAREST ELECTROLUX AUTHORIZED SERVICER. A microwave oven should never be serviced by a "do-it-yourself" repair person. NOTES If time appearing in the display is counting down very rapidly, check Demonstration Mode on page 27 and cancel. SPECIFICATIONS AC Line Voltage: AC Power Required: Single phase 120V, 60Hz, AC only 1600W 14.2 amps. (for FGMV173QF, FGMV173QB/W/Q/M) Output Power*: Frequency: Outside Dimensions: Cavity Dimensions: Microwave oven Capacity***: Cooking Uniformity: Weight: Work/Night Light: Oven Light: 1000 W 2450 MHz (Class B/Group2)** 29 7/8"(W) x 16 13/32"(H) x 15 1/32"(D) 2015/16"(W) x 9 7/16"(H) x 14 13/ 32"(D) 1.7 Cu.Ft. Turntable Approx. (net) 61.7 lb, (gross) 28.0 lb 2 bulbs 30w each (incandescent light bulbs) 1 bulb 30w (incandescent light bulbs) * The International Electrotechnical Commission's standardized method for measuring output wattage. This test method is widely recognized. ** This is the classification of ISM (Industrial, Scientific and Medical) equipment described in the International Standard CISPR11. *** Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for holding food is less. In compliance with standards set by: FCC - Federal Communications Commission Authorized. DHHS - Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I, Subchapter J. NHW - Department of National Health and Welfare of Canada. - This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc. - This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc. for use in USA or Canada. 3 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33

AC Line Voltage:
Single phase 120V, 60Hz, AC only
AC Power Required:
1600W 14.2 amps. (for FGMV173QF, FGMV173QB
Output Power*:
1000 W
Frequency:
2450 MHz (Class B/Group2)**
Outside Dimensions:
29 /8”(W) x 16 /
”(H) x 15
1
/32”(D)
Cavity Dimensions:
20
”(W) x 9
7
/16”(H) x 14
/32”(D)
Microwave oven Capacity***:
1.7 Cu.Ft.
Cooking Uniformity:
Turntable
Weight:
Approx. (net) 61.7 lb, (gross) 28.0 lb
Work/Night Light:
2 bulbs 30w each (incandescent light bulbs)
Oven Light:
1 bulb 30w (incandescent light bulbs)
SERVICE CALL CHECK
SPECIFICATIONS
Please check the following before calling for service:
Place one cup of water in a glass measuring cup in the microwave oven and close the door securely.
Operate the microwave oven for one minute at HIGH 100%.
A
Does the microwave oven light come on?
YES ____
NO ____
B
Does the cooling fan work? (Put your hand on the louver above the
.)
YES ____
NO ____
C
Does the turntable rotate? (It is normal for the turntable to turn in either direction.)
YES ____
NO ____
D
Is the water in the microwave oven warm?
YES ____
NO ____
If “NO” is the answer to any of the above questions,
please check electrical outlet, fuse and/or circuit
breaker. If they are functioning properly, CONTACT
YOUR NEAREST ELECTROLUX AUTHORIZED SER-
VICER.
A microwave oven should never be serviced by a
“do-it-yourself” repair person.
*
The International Electrotechnical Commission’s standardized method for measuring output wattage. This test method
is widely recognized.
**
This is the classification of ISM (Industrial, Scientific and Medical) equipment described in the International Standard CISPR11.
***
Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for holding food is less.
In compliance with standards set by:
FCC
- Federal Communications Commission Authorized.
DHHS
-
Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I, Subchapter J.
NHW
-
Department of National Health and Welfare of Canada.
-
This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.
-
This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc. for use in
USA or Canada.
NOTES
very rapidly, check Demonstration Mode on page 2
and cancel.
/W/Q/M)
/
15
16
13
7
13
32
3
If time appearing in the display is counting down
Control Panel
7
2