30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS (Models with an Electric Oven and a Gas Cooktop) INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. FOR YOUR SAFETY: - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Refer to your serial plate for - WHAT TO DO IF YOU SMELL GAS: applicable agency certification • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency or the gas supplier. For existing 29" (73.7 cm) cutout width opening, you must call the Service Center for optional thinner side panels. Also you must prepare the countertop edge as shown in the "Countertop Preparation" section (see page 7). WALL 30" Min. (76.2 cm Min.) These surfaces should be flat & leveled (hatched area). 1/2" Min. Shave 1 ½" Max. (3.8 cm Max.) 5" Min. (12.7 cm Min.) From Wall Both Sides 30" Min. (76.2 cm) Min. (see Note 3) 18" Min. (45.7 cm) Min. Raised Edge E 1/4" min. to Clear Space for a 31½" (81 cm) Wide Cooktop. 31 1/2" (81 cm) Exact G F 1/2" min. Approx. 1 7/8" (4.8 cm) 13" (33 cm) Locate Cabinet Doors 1" (2.5 cm) Min. from IMPORTANT: Cutout Opening. Cabinet and E countertop width should match the E cutout width. 24" Min. (61 cm Min.) Grounded Jonction Box or Wall Outlet Should Be Located 8" to 17" (20.3 cm to 43.2 cm) From Right Cabinet and 2" to 4" (5.1 cm to 10.2 cm) From Floor. Do not install the unit in the cabinet before reading next page. A. HEIGHT B. WIDTH C. COOKTOP D. DEPTH TO E. CUTOUT WIDTH *** WIDTH FRONT OF RANGE (Countertop and Cabinet) F. CUTOUT DEPTH G. HEIGHT OF COUNTERTOP 35 5/8" (90.5 cm) - 30" (76,2 cm) 31½" (80 cm) 28 5/16" (71,9 cm) 36 5/8" (93 cm) 30±1/16" (76,2±0,15 cm) 21 3/4" (55,2 cm) Min. 36 5/8" (93 cm) Max. 22 1/8" (56,2 cm) Max 35 5/8" (90.5 cm) Min. 24" (61 cm) Min. with backguard NOTE: Wiring diagram for these appliances are enclosed in this booklet. Printed in United States 1 P/N 318201671 (0711) Rev. D English - pages 1-12 Español - páginas 13-24 Français - pages 25-36 Wiring Diagrams - pages 39-40

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
(Models with an Electric Oven and a Gas Cooktop)
P/N 318201671 (0711) Rev. D
English – pages 1-12
Español – páginas 13-24
Français – pages 25-36
Wiring Diagrams - pages 39-40
If the information in this manual is not followed exactly, a fire
or explosion may result causing property damage, personal injury or death.
FOR YOUR SAFETY:
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
NOTE: Wiring diagram for these appliances are enclosed in this booklet.
Printed in United States
Refer to your serial plate for
applicable agency certification
1/2” Min.
1/4” min.
1/2” min.
WALL
5" Min.
(12.7 cm Min.)
From Wall Both Sides
30" Min.
(76.2 cm Min.)
30" Min. (76.2 cm)
Min. (see Note 3)
18" Min.
(45.7 cm) Min.
Approx. 1 7/8"
(4.8 cm)
Grounded Jonction Box or Wall Outlet Should Be
Located 8" to 17" (20.3 cm to 43.2 cm) From Right
Cabinet and 2" to 4" (5.1 cm to 10.2 cm) From Floor.
Locate Cabinet Doors 1"
(2.5 cm) Min. from
Cutout Opening.
F
G
E
31 1/2"
(81 cm)
Exact
13"
(33 cm)
24" Min.
(61 cm Min.)
Shave
Raised
Edge
to Clear
Space
for a 31½"
(81 cm) Wide
Cooktop.
1 ½" Max.
(3.8 cm Max.)
These surfaces
should be flat & leveled
(hatched area).
35 5/8" (90.5 cm) -
36 5/8" (93 cm)
30" (76,2 cm)
28 5/16" (71,9 cm)
30±1/16"
(76,2±0,15 cm)
21 3/4" (55,2 cm) Min.
22 1/8" (56,2 cm) Max
24" (61 cm) Min. with
backguard
36 5/8" (93 cm) Max.
35 5/8" (90.5 cm) Min.
A
. HEIGHT
B
.
WIDTH
D
.
DEPTH TO
FRONT OF RANGE
E
.
CUTOUT WIDTH ***
(Countertop and
Cabinet)
F
.
CUTOUT
DEPTH
G
.
HEIGHT
OF COUNTERTOP
31½" (80 cm)
C.
COOKTOP
WIDTH
For existing 29" (73.7 cm) cutout width
opening, you must call the Service Center for
optional thinner side panels. Also you must
prepare the countertop edge as shown in the
"Countertop Preparation" section (see page 7).
IMPORTANT:
Cabinet and
countertop
width
should
match the
cutout
width.
E
E
Do not install the unit in the cabinet before reading next page.