Merchandise Information Sheet MIS 46-Freezers rev 0 October 20, 2004 Installation and Leveling of Stainless Steel All Refrigerator, All Freezer Division: 46 Installation All Refrigerator and All Freezer Topic: Instructions for installing and leveling. Electrical Information: 1. Each unit must be plugged into its own dedicated 115 Volt, 60 Hz., AC circuit. 2. The power cord of each unit is equipped with a three-prong grounding plug for protection against shock hazards. It must be plugged directly into a properly grounded three-prong receptacle, protected with a 15 amp time delay fuse or circuit breaker. 3. Do Not connect units to a Ground Fault Circuit Interrupter (GFCI) circuit. Location: 1. The units must be installed on a floor that is level and strong enough to support a fully loaded refrigerator and freezer. 2. Consider water supply availability for models equipped with an automatic ice maker. Clearances: 1. Allow the following clearances for ease of installation, proper air circulation, plumbing and electrical connections. • Sides 3/8" • Top & Back ------ 1" • Between units ---------- 3/16" 2. Do Not block toe grille on the lower front of the units. Sufficient air circulation is essential for the proper operation of the units. Page 1 of 3 PN: 297078900

  • 1
  • 2
  • 3

Merchandise Information Sheet
MIS 46-Freezers rev 0
October 20, 2004
Installation and Leveling of Stainless Steel
All Refrigerator, All Freezer
Division: 46
Installation
All Refrigerator and All Freezer
Topic:
Instructions for installing and leveling.
Electrical Information:
1. Each unit must be plugged into its own dedicated 115 Volt, 60 Hz.,
AC circuit.
2. The power cord of each unit is equipped with a three-prong grounding
plug for protection against shock hazards.
It must be plugged directly
into a properly grounded three-prong receptacle, protected with a 15
amp time delay fuse or circuit breaker.
3.
Do Not
connect units to a Ground Fault Circuit Interrupter (GFCI)
circuit.
Location:
1. The units must be installed on a floor that is level and strong enough
to support a fully loaded refrigerator and freezer.
2. Consider water supply availability for models equipped with an
automatic ice maker.
Clearances:
1. Allow the following clearances for ease of installation, proper air
circulation, plumbing and electrical connections.
Sides -------------- 3/8”
Top & Back ------ 1”
Between units ---------- 3/16”
2.
Do Not
block toe grille on the lower front of the units. Sufficient air
circulation is essential for the proper operation of the units.
Page 1 of 3
PN: