Fujitsu MHN2200AT Manual/User Guide - Page 167
Read Sectors command protocol, For transfer of a sector of data
View all Fujitsu MHN2200AT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 167 highlights
5.4 Command Protocol words, the host should receive the relevant sector of data (512 bytes of uninsured dummy data) or release the DRQ status by resetting. Figure 5.3 shows an example of READ SECTOR(S) command protocol, and Figure 5.4 shows an example protocol for command abort. Figure 5.3 Read Sector(s) command protocol IMPORTANT For transfer of a sector of data, the host needs to read Status register (X'1F7') in order to clear INTRQ (interrupt) signal. The Status register should be read within a period from the DRQ setting by the C141-E120-02EN 5-91
5.4
Command Protocol
C141-E120-02EN
5-91
words, the host should receive the relevant sector of data (512 bytes of uninsured
dummy data) or release the DRQ status by resetting.
Figure 5.3 shows an example of READ SECTOR(S) command protocol, and
Figure 5.4 shows an example protocol for command abort.
Figure 5.3
Read Sector(s) command protocol
IMPORTANT
For transfer of a sector of data, the host needs to read Status register
(X’1F7’) in order to clear INTRQ (interrupt) signal. The Status
register should be read within a period from the DRQ setting by the