Figure 3-3. Shield Termination on Backshell Assembly Prepare all of the shielded cables as shown in Figure 3-2. Refer to Figure 3-3 for details of the shield termination to the connector backshell. 1. At the end of the shielded cable (11), strip back a 2" maximum length of the jacket to expose the braid. Remove this exposed braid. Carefully score the jacket 1/4" to 5/16" from the end and remove the jacket to leave the braid exposed. NOTE Solder sleeves with pre-installed shield drains may be used instead of separate shield terminators and individual wires. 2. Connect a 20 or 22 AWG wire (13) to the exposed shield of the prepared cable assembly. (See Figure 3-2). AC 43.13 maybe a helpful reference for termination techniques. GAD 43 Installation Manual 190-00899-00 Page 3-5 Rev. B

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

GAD 43 Installation Manual
Page 3-5
190-00899-00
Rev. B
Figure 3-3. Shield Termination on Backshell Assembly
Prepare all of the shielded cables as shown in Figure 3-2. Refer to Figure 3-3 for details of the shield
termination to the connector backshell.
1.
At the end of the shielded cable (11), strip back a 2” maximum length of the jacket to expose the
braid. Remove this exposed braid. Carefully score the jacket 1/4” to 5/16” from the end and remove
the jacket to leave the braid exposed.
NOTE
Solder sleeves with pre-installed shield drains may be used instead of separate shield
terminators and individual wires.
2.
Connect a 20 or 22 AWG wire (13) to the exposed shield of the prepared cable assembly. (See Figure
3-2). AC 43.13 maybe a helpful reference for termination techniques.