Garmin Index BPM Smart Blood Pressure Monitor Owners Manual - Page 26

Maintenance, frequency, Band MHz, Service, Modulation, Maximum, power W, Distance, IMMUNITY

Page 26 highlights

Test frequency (MHz) Band (MHz) Service Modulation Maximum power (W) Distance (m) IMMUNITY TEST LEVEL (V/m) Compliance level (V/m for home healthcare) 1 720 1 845 1 970 1 700-1 990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1, 2, 3, 4, 25 UMTS Pulse modu­ lation 2 217 Hz 0,3 28 28 2 450 2 400-2 570 Bluetooth, WLAN, 802.11 b/g/n, RFID, 2450, LTE Band 7 Pulse modu­ lation 2 217 Hz 0,3 28 28 5 240 5 500 5 785 5 100-5 800 WLAN 802.11 a/n Pulse modu­ lation 0,2 217 Hz 0,3 9 9 NOTE: If necessary to achieve the IMMUNITY TEST LEVEL, the distance between the transmitting antenna and the ME EQUIPMENT or ME SYSTEM may be reduced to 1 m. The 1 m test distance is permitted by IEC 61000-4-3. NOTE: For some services, only the uplink frequencies are included. NOTE: The carrier shall be modulated using a 50% duty cycle square wave signal. Maintenance • No firmware update is needed during the service life of this product. • On very rare occasions, you might need to reinstall the firmware on the device due to hardware malfunction. In this case, the intended use remains unchanged. • Any modification or change to the firmware is prohibited. 22 Device Information

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Test
frequency
(MHz)
Band (MHz)
Service
Modulation
Maximum
power (W)
Distance
(m)
IMMUNITY
TEST LEVEL
(V/m)
Compliance
level (V/m
for home
healthcare)
1 720
1 700-1 990
GSM 1800
CDMA 1900
GSM 1900
DECT
LTE Band 1,
2, 3, 4, 25
UMTS
Pulse modu²
lation
217 Hz
2
0,3
28
28
1 845
1 970
2 450
2 400-2 570
Bluetooth,
WLAN,
802.11
b/g/n, RFID,
2450, LTE
Band 7
Pulse modu²
lation
217 Hz
2
0,3
28
28
5 240
5 100-5 800
WLAN
802.11 a/n
Pulse modu²
lation
217 Hz
0,2
0,3
9
9
5 500
5 785
NOTE:
If necessary to achieve the IMMUNITY TEST LEVEL, the distance between the transmitting antenna
and the ME EQUIPMENT or ME SYSTEM may be reduced to 1 m. The 1 m test distance is permitted by IEC
61000-4-3.
NOTE:
For some services, only the uplink frequencies are included.
NOTE:
The carrier shall be modulated using a 50% duty cycle square wave signal.
Maintenance
No firmware update is needed during the service life of this product.
On very rare occasions, you might need to reinstall the firmware on the device due to hardware malfunction.
In this case, the intended use remains unchanged.
Any modification or change to the firmware is prohibited.
22