Chapter 7: Troubleshooting Additional beep codes provided by optional Intel Management Modules In addition to the beep codes above, the following additional beep codes are provided if an Intel Management Module is installed: Beep Codes 1 1-5-1-1 1-5-2-1 1-5-2-3 1-5-2-4 1-5-4-2 1-5-4-3 1-5-4-4 Description Control panel CMOS clear has been initiated Processor failure. Reseat or replace the failed processor. No processor is installed or the CPU 1 socket is empty. Reseat or replace the failed processor. Processor configuration error or CPU 1 socket is empty. Reseat or replace the failed processor. In a two-processor system, make sure the processors are identical. Front-side bus select configuration error. DC power unexpectedly lost. Chipset control failure. Power control failure. LED information The system board in this server includes LEDs that can assist you in troubleshooting your system. See the following table for a description of these LEDs and the information they provide: LED Name ID System Fault Function Aid in server identification from the back panel Visible fault warning IDE Activity Front panel Location Front panel and left back of system board Color Blue Description On = Server identification enabled Front panel and left back of system board Front panel and left side of system board Green or Orange Green ■ On = No fault ■ Green blink = Degraded ■ Orange = Critical error or non-recoverable ■ Orange blink = Non critical Blinking = Drive active 152 www.gateway.com