GE 1500VA User Manual - Page 7
LED display & buzzer alarm list - avr
UPC - 871437958956
View all GE 1500VA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
GE 3. LED Overload/ replace battery/ UPS fault (red) This red LED will blink and the alarm sounds 2 beeps every second when the load connected to the "Battery backup & surge protection" outlets exceeds the nominal capacity of the UPS. The UPS will automatically shut down after beeping for ten seconds. The LED will blink and the alarm sounds 3 beeps every 30 seconds when the UPS detects that the battery needs to be replaced soon. Allow the UPS to recharge the battery for at least 4 hours. If the LED lights again after 4 hours of charging, the battery needs to be replaced to ensure full protection for your equipment. Contact your dealer. When the UPS detects a hardware fault, the red LED will illuminate, the alarm will sound continuously and the UPS will shut down. In some instances the fault condition may be cleared by switching the UPS off and then on again. 4. Input socket AC mains supply to the UPS. 5. Outlets "Surge protection" The outlets provide full time protection from surges and spikes. Peripheral equipment that does not require power during a mains power failure, e.g. printers, scanners, fax machines, or speakers can be connected to these outlets. 6. Outlets "Battery backup & surge protection" The outlets not only provide full time surge protection but also provide emergency battery backup power during a mains power failure such as a blackout or brownout. 7. Phone/FAX protection The RJ11 jacks can provide protection against surges and spikes on your phone line. 8. RJ11 USB communication port The provided GE monitoring and shutdown software can be automatically configured to save your files and shut down your computer in the event of a prolonged power outage. Refer to the manual that came with the software. 9. Circuit breaker In case of a severe overload the circuit breaker may trip. The button will come out, the UPS is disconnected from the mains and output power is lost. In this situation reduce the load connected to the "Battery backup & surge protection" and/or "Surge protection" outlets of the UPS. Subsequently reset the circuit breaker by pushing the button back in. LED display & buzzer alarm list Green LED On On On X Blinking Blinking X Red LED X Blinking Blinking On X Blinking On Alarm X 3 beeps every 30 seconds 2 beeps every second Continuous buzzer 1 beep every 10 seconds 2 beeps every 5 seconds Continuous buzzer UPS Status Indication On mains (bypass / AVR mode) Replace battery Over load Fault / output short circuit On battery Battery low Battery over voltage modifications reserved GE_UPS_OPM_VCL_XXX_0K4_1K5_XGB_V013 Page 7/10 User manual - VCL Series UPS 400-1500VA V013 - GB